Error description
When IBM Explorer for z/OS Version 3.0.1.6 or Rational Developer for System z - RDz - v9.5.1.4, are installed on a remote network drive as part of a Virtual Desktop Infrastructure (VDI), then expanding a JES filter can take few minutes. Steps to reproduce: - Map a network drive to an RDz/IDz installation - Start RDz/IDz - Connect to z/OS - Expand filter My Jobs and observe the workbench being unresponsive for 30 seconds or more.
Local fix
Problem does not happen with a new workspace or after having cleared the cache in menu Window > Preferences > Remote Systems > File Cache and click on Clear Cached Files
Problem summary
When using a work space that is located on a network drive, expanding JES filters can be time consuming.
Problem conclusion
To read the JES filter results, a file is downloaded from the host to the RemoteSystemTempFiles project (where all remote downloads go) of the user workspace. To ensure the downloaded file is in sync with the workspace, a call is made to sync up everything in the RemoteSystemTempFiles. Where there are a lot of downloaded files and a user does this over a network, that call is very expansive but also unnecessary since all that is needed to sync up is to refresh the parent folder of the downloaded JES filter results file.
Temporary fix
Comments
APAR Information
APAR number
PI88948
Reported component name
EXP FOR Z/OS CL
Reported component ID
5655EXP00
Reported release
301
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-10-17
Closed date
2018-01-24
Last modified date
2018-01-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
EXP FOR Z/OS CL
Fixed component ID
5655EXP00
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSBDYH","label":"IBM Explorer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"301","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
24 January 2018