A fix is available
APAR status
Closed as program error.
Error description
When moving a value into a display numeric item with a floating insertion symbol, for example PIC -(3)9.9(2) where the "-" is floating, the pattern for an EDMK (EDIT AND MARK) instruction is copied to a compiler temporary item, but the pattern is a byte longer than that temporary. This overlays the subsequent item, typically another temporary or other compiler generated item. This may have no apparent effect, but in some cases may lead to abends, for example if the compiler generated item contains an address, like the return address of a PERFORMed paragraph or section. ABENDS0C4 ABEND0C4
Local fix
Use OPT(0)
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V6.1 compiling * * and running programs using compiler options * * OPT(1|2) and the programs move data into a * * NUMERIC-EDITED data item with a minus sign * * or currency symbol. * * * **************************************************************** * PROBLEM DESCRIPTION: ABEND 0C4 at runtime: The MOVE * * operation may use an additional byte * * of data. * * * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * * * **************************************************************** When attempting to generate more efficient code for MOVEs to NUMERIC-EDITED data items with a minus sign or currency symbol, the compiler incorrectly determined that the receiver had a length one greater than its actual length, so when the MOVE was executed, one byte of additional data was incorrectly overwritten.
Problem conclusion
The compiler was fixed to use the correct length for MOVEs to NUMERIC-EDITED data.
Temporary fix
Comments
APAR Information
APAR number
PI80051
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
610
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-04-17
Closed date
2017-06-24
Last modified date
2017-07-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGYQCBE
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R610 PSY UI48286
UP17/06/30 P F706
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.