A fix is available
APAR status
Closed as program error.
Error description
At OPT(1/2), the compiler abend with message MSGIGYCB7104-U Internal error while compiling function 'XXXXX'. Failed assertion on /build/cob/6.1/tr.r15.cobol-prod- opt/tr.source/omr/il/node/OMRNode_inlines.hpp:61. This problem can affect Enterprise COBOL users compiling COBOL programs at OPT(1|2) that CALL 'DFHEI1' without any parameters.
Local fix
COmpile at OPT(0)
Problem summary
**************************************************************** * USERS AFFECTED: Enterprise COBOL V6.1 users compiling COBOL * * programs at OPT(1|2) that contain CALL * * 'DFHEI1' statements without any USING * * parameters. * * * **************************************************************** * PROBLEM DESCRIPTION: Compiler ABORT with message * * MSGIGYCB7104-U Internal error while * * compiling function 'XXXXX'. Failed * * assertion on * * /build/cob/6.1/tr.r15.cobol-prod- * * opt/tr.source/omr/il/node/OMRNode_inli * * nes.hpp:61. * * * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * * * **************************************************************** While performing analysis on CALL statements to the CICS interface DFHEI1, the compiler assumed that calls to DFHEI1 must have parameters.
Problem conclusion
The compiler was fixed to no longer assume calls to DFHEI1 must have parameters.
Temporary fix
Comments
APAR Information
APAR number
PI80028
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
610
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-04-14
Closed date
2017-04-25
Last modified date
2017-05-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGYQCBE
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R610 PSY UI46711
UP17/04/29 P F704
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.