A fix is available
APAR status
Closed as program error.
Error description
Panel ADB2IIT via I command from panel GOCMENU does not list parameters between length 1 to 72 in the displayed data set. As a result, the alternate parameters (such as GOCGAWL) generated by this panel extend beyond column 72, and are not included in the ALTSHV variable pool. When generating an apply job, and attempting to specify these parameters under the ALTSHV DD statement, the following error may result: FUNCTION = ADBGAJOB, LINE 11979: If gocunlt = 'P' | (gocunlt = 'H' & gocgawl ^= RC = 8 ZERRMSG = ISPT034 ZERRSM = Novalue condition raised for variable GOCGAWL ZERRLM = Error executing EXEC - now terminating
Local fix
n/a
Problem summary
**************************************************************** * USERS AFFECTED: Users of the DB2 Administration Tool * * for z/OS and DB2 Object Comparison * * Tool for z/OS who use alternate * * parameters input. * **************************************************************** * PROBLEM DESCRIPTION: Error 'ISPT034 A novalue condition * * is raised in variable GOCGAWL' * * when generating an apply job and * * using alternate parameter input * * in ALTSHV. * **************************************************************** * RECOMMENDATION: * **************************************************************** The GOCGAWL variable was not placed in ALTSHV variable pool because it was not formatted properly.
Problem conclusion
The formatting problem has been resolved.
Temporary fix
Comments
APAR Information
APAR number
PI77758
Reported component name
DB2 OBJECT COMP
Reported component ID
5697G6400
Reported release
B20
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-03-07
Closed date
2017-08-25
Last modified date
2017-09-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI49871 UI49872
Modules/Macros
GOCCMP GOCGCMP
Fix information
Fixed component name
DB2 OBJECT COMP
Fixed component ID
5697G6400
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUVH","label":"IBM Db2 Object Comparison Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"11.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
12 February 2021