A fix is available
APAR status
Closed as program error.
Error description
Loop occurs after CEMT SET PROG(*) PHA command. The CEMT task abends with message: . DFHLD0004 A possible loop has been detected at offset X'FFFF' in module DFHLDLD3. . If ICVR is turned off for the task, CEMT never finishes. CICS trace shows that the CEMT task processes a number of programs, then goes into a loop. The loop is in DFHLDLD3, proc CPE_EXPLODE, and MVS system trace shows that the range of the loop is DFHLDLD3 +x874 to x88E (base level). . The problem is that the APE +x28 (field APE_OLDER_APE) for a program points to itself. Problem occurs when modules are used out of the LPA. . Additional symptoms/search keywords: KIXREVxxx REFRESH_PROGRAM DFHAPATT APE_OLDER
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICS Users. * **************************************************************** * PROBLEM DESCRIPTION: Loop in DFHLDLD3 after a CEMT SET * * PROGRAM PHASEIN and program is loaded * * from the LPA. * **************************************************************** * RECOMMENDATION: . * **************************************************************** It is possible to suffer an abendAEXZ following a CEMT SET PROGRAM PHASEIN (or NEWCOPY) if the program being the subject of the PHASEIN has been loaded from the LPA. The problem happens because code in DFHLDLD3 is browsing through the Active Program Elements ( APE ) but the chaining fields in the APE have been incorrectly updated to point to itself because of changes to the optimization level of the compiler. Additional keywords: APE_OLDER_APE APE_YOUNGER_APE
Problem conclusion
DFHLDLD1 has been changed to revert the level of optimisation.
Temporary fix
Comments
APAR Information
APAR number
PI77657
Reported component name
CICS TS Z/OS V5
Reported component ID
5655Y0400
Reported release
000
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-03-06
Closed date
2017-05-11
Last modified date
2017-06-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI47171 PI83337
Modules/Macros
DFHLDLD1
Fix information
Fixed component name
CICS TS Z/OS V5
Fixed component ID
5655Y0400
Applicable component levels
R000 PSY UI47171
UP17/05/15 P F705
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3","Edition":"","Line of Business":{"code":"","label":""}}]