You upgraded to DB2 Version 12 and the VIDDB2 job fails with ABENDU3130 running VIDSPLIT in the SPLIT jobstep. Additional Symptom(s) Search Keyword(s): KIXREVRJL Migration KIXDCFDB212 installation DB2 V12 CICSVT DB2 V12.1
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of CICS VSAM Transparency * **************************************************************** * PROBLEM DESCRIPTION: Abend U(3130) when running DDM * * Generation under DB2V12. * **************************************************************** * RECOMMENDATION: * **************************************************************** DDM Generation fails under DB2 V12. When executed under DB2 V12, program VIDSPLIT fails with abend U3130 because that version of DB2 is not in the CICS VT list of supported versions.
Problem conclusion
Program VIDSPLIT needs to ascertain the DB2 version in order to split the SQLDSECT fields. DB2 Version 8 and higher have the same SQLDSECT structure. The VIDSPLIT code has been changed to process DB2 V12 or higher on the assumption that the SQLDSECT DSECT remains the same for future releases of DB2. 200Y VIDSPLIT CIC0506T/K CIC0505T/K
Temporary fix
Comments
APAR Information
APAR number
PI74775
Reported component name
CICS VSAM TRANS
Reported component ID
5655Y0100
Reported release
200
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-01-11
Closed date
2017-01-19
Last modified date
2024-04-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI44074
Modules/Macros
VIDSPLIT
Fix information
Fixed component name
CICS VSAM TRANS
Fixed component ID
5655Y0100
Applicable component levels
R200 PSY UI44074
UP17/01/21 P F701
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSBQNK","label":"CICS VSAM Transparency for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"200","Line of Business":{"code":"LOB70","label":"Z TPS"}}]
Document Information
Modified date:
22 April 2024