Fixes are available
APAR status
Closed as program error.
Error description
Program calling the DateTimeLib.mdy function, which in turn passes erroneous range values, returns an obscure date instead of throwing an exception as expected ie. d1 date = DateTimeLib.mdy(31, 12, 2016); SysLib.writeStdout(d1); Output shows the date as: 12/07/2018 In this scenario an exception should be thrown as per the following example: (15:06:20> .--> com.datesMdy.main (15:06:20> EGL0114E The DateTimeLib.mdy function cannot convert the 31, 12, and 2016 values into a month, day, and year. (15:06:20> EGL0002I The error occurred in datesMdy processing the main function. (15:06:20> endRunUnit datesMdy (error termination) with returnCode=693 EGL0114E The DateTimeLib.mdy function cannot convert the 31, 12, and 2016 values into a month, day, and year. EGL0002I The error occurred in datesMdy processing the main function.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * EGL Java users * **************************************************************** * PROBLEM DESCRIPTION: * * Program calling the DateTimeLib.mdy function, which in turn * * passes erroneous range values, returns an obscure date * * instead * * of throwing an exception as expected. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
The problem is fixed.
Temporary fix
Comments
APAR Information
APAR number
PI73154
Reported component name
RATL BUS DEV
Reported component ID
5724S5000
Reported release
950
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-12-02
Closed date
2019-01-18
Last modified date
2019-01-18
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL BUS DEV
Fixed component ID
5724S5000
Applicable component levels
R911 PSY
UP
R950 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"950","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: