A fix is available
APAR status
Closed as program error.
Error description
With the TEST compiler option, the compiler may abort due to an out of memory condition with message MSGIGYIN5125-U The compilation was terminated due to a compiler error in phase id: "IGYCINIT".
Local fix
Compile with NOTEST
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V5.2 compiling * * programs with compiler option TEST. * **************************************************************** * PROBLEM DESCRIPTION: Compiler ABORT due to out of memory * * with message MSGIGYIN5125-U The * * compilation was terminated due to a * * compiler error in phase id: "IGYCINIT". * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** Extra debug information generated with TEST requires more compiler memory.
Problem conclusion
Updated internal debug information storage generated with TEST option to use less memory.
Temporary fix
Comments
APAR Information
APAR number
PI98511
Reported component name
ENT COBOL FOR Z
Reported component ID
5655W3200
Reported release
520
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-05-29
Closed date
2018-06-10
Last modified date
2018-07-17
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCBE IGYCCBE IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYECWI IGYMSGE IGYMSGK IGYMSGT
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655W3200
Applicable component levels
R520 PSY UI56404
UP18/06/21 P F806
R521 PSY UI56405
UP18/06/22 P F806
R522 PSY UI56406
UP18/06/22 P F806
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"LOB17","label":"Mainframe TPS"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
17 July 2018