APAR status
Closed as program error.
Error description
A stub running on Linux can take 2 seconds to process Excel test data. This results in a 2 second delay when responding to each received message. The problem can be seen in the Agent log as follows: [RunTests/instance2 (1)]: [24/04/2018, 11:20:57.855] [Debug] Instance 19: Tag read : PROJECT/ROOT_DIRECTORY (/var/myWorkspace/ita/7539796174161277891/engines/1/ProjectFiles ) 2 second delay [RunTests/instance2 (1)]: [24/04/2018, 11:20:59.954] [Debug] Instance 19: Tag read : Name () STEPS TO REPRODUCE: 1. Create a stub that performs a Test Data Lookup using Excel test data. 2. Deploy to RIT-Agent with Debug logging enabled. 3. Send a message to the stub. EXPECTED RESULTS: The stub responds in a few milliseconds ACTUAL RESULTS: The stub responds in 2 seconds. The RIT-Agent log shows the delay. WORKAROUND: Convert the test data to CSV and redesign the stub to use that file.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of Excel test data * **************************************************************** * PROBLEM DESCRIPTION: * * On some operating systems, previous releases of Integration * * Tester did not correctly detect when a file used as the * * source of a Test Data resource was modified. This might lead * * to data being refreshed unnecessarily. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
Fixed in 9.2.0.1
Temporary fix
Comments
APAR Information
APAR number
PI97634
Reported component name
RATL INTEGRA TE
Reported component ID
5725G79IT
Reported release
910
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-05-04
Closed date
2018-07-03
Last modified date
2018-07-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL INTEGRA TE
Fixed component ID
5725G79IT
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSBLQQ","label":"IBM Rational Test Workbench"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"910","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
03 July 2018