IBM Support

PI95092: INCORRECT OUTPUT WHEN COMPILED WITH TRUNC(OPT)

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Incorrect output may be seen on a signed binary integer when
    compiling with TRUNC(OPT) option.
    

Local fix

  • Use TRUNC(BIN)
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL 6.2 compiling and  *
    *                 running programs with either the TRUNC(OPT)  *
    *                 or TRUNC(BIN) option and the program         *
    *                 contains a comparison between a USAGE        *
    *                 BINARY/COMP/COMP-4 data item and a literal   *
    *                 whose binary representation requires more    *
    *                 bytes than the data item to which it is      *
    *                 being compared.                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: Incorrect runtime result.               *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    The compiler was representing the literal internally with an
    incorrect size causing it to generate incorrect code for the
    comparison.
    

Problem conclusion

  • The compiler was updated to represent the literal in such
    comparisons with the correct size.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI95092

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    620

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-03-13

  • Closed date

    2018-03-15

  • Last modified date

    2018-04-03

  • APAR is sysrouted FROM one or more of the following:

    PI92059

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • IGY8RWTU IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN
    IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4
    IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT
    IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8
    IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0
    IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOPI  IGYCOSCN
    IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT  IGYCSCAN
    IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5
    IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV   IGYEQCWI IGYMSGE
    IGYMSGK  IGYMSGT  IGYQCBE  IGYWCL   IGYWCLG  IGYZQDRV IGYZQENU
    IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R620 PSY UI54510

       UP18/03/28 P F803

  • R621 PSY UI54511

       UP18/03/28 P F803

  • R622 PSY UI54512

       UP18/03/28 P F803

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
12 December 2023