APAR status
Closed as program error.
Error description
If you have an admin portlet (Web Content Syndicators or Web Content Libraries) on the same Portal page as the autoring portlet, the buttons in the authoring portlet do not work on items with RTE fields when open in edit mode.
Local fix
Problem summary
The admin portlet was setting the form loaded flag to false which prevented the RTE fields from initialising and because buttons are disabled until the RTEs are initialised, they remained inactive indefinitely.
Problem conclusion
The admin portlet no longer affects the form loaded flag.
Temporary fix
Comments
APAR Information
APAR number
PK90167
Reported component name
WEBSPHERE PORTA
Reported component ID
5724E7600
Reported release
610
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-06-29
Closed date
2009-06-29
Last modified date
2009-06-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBSPHERE PORTA
Fixed component ID
5724E7600
Applicable component levels
R61A PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSHRKX","label":"WebSphere Portal"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.1","Line of Business":{"code":"LOB31","label":"WCE Watson Marketing and Commerce"}}]
Document Information
Modified date:
21 December 2021