A fix is available
APAR status
Closed as program error.
Error description
If the classic command ATRQ is protected the specification of an ATF background trace collection in panel CUA KD2DATF0 is allowed while it should ask the user for a password.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - Classic Interface * * - CUA Interface * **************************************************************** * PROBLEM DESCRIPTION: ATF CUA BACKGROUND TRACE COLLECTION * * SPECIFICATION NOT HANDLED PROPERLY IN * * SECURITY CONTEXT * * * **************************************************************** * RECOMMENDATION: Apply this PTF * * * **************************************************************** PROBLEM SUMMARY: ATF CUA BACKGROUND TRACE DOES NOT CHECK AUTHORIZATION BEFORE EXECUTING OMEGAMON COMMANDS PROBLEM CONCLUSION: CHANGE LOGIC TO ADD CHECK AUTHORIZATION BEFORE EXECUTING OMEGAMON COMMANDS
Problem conclusion
CHANGE LOGIC TO ADD CHECK AUTHORIZATION BEFORE EXECUTING OMEGAMON COMMANDS
Temporary fix
Comments
APAR Information
APAR number
PK88902
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-06-15
Closed date
2009-11-20
Last modified date
2009-12-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK52116 UK52117
Modules/Macros
KD2CHIF KD2CIF KD2DATB0 KD2DATB3 KD2DATF0 KD2DATF1 KD2DATF2 KD2DATF3 KD2OUDAD KD2PPSWP KD2PSA3P KD2RECSD KD2REDMD KD2RHBUD KD2RHEPD KD2RHLKD KD2UTDBP KD2UTDLO KD2UTDLW KD2UTDPD KD2UTDSC KD2UTDSS KD2UTDTD KD2UTGBP KD2UTGLO KD2UTSLC KD2VARCD KD2VARC7 KD2VASPD KD2VASP7 KD2VBPDD KD2VBPSN KD2VCSQD KD2VCSQ6 KD2VDDP7 KD2VDSSD KD2VDTDD KD2VGBMD KD2VGLKD KD2VHBDD KD2VHGBD KD2VHGLD KD2VHLMD KD2VHPTD KD2VHQDD KD2VLKWD KD2VLOGD KD2VLOGM KD2VLOG7 KD2VLOKD KD2VRLSD KD2VRLS7 KD2VSQLD KD2VSTOP KD2VTBPA KD2VTGBP KD2VTGLO KD2VTHDD KD2VTHD6 KD2VTLOC KD2VTPDD KD2VTPSD KD28DTDD KD29PTSD KD29RLMD KD29SA3P KD29TCAN KD29TIIO KD29TPDD KD29TPSD KD29UDAD KO2OTHBB KO2OTHDB
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: