A fix is available
APAR status
Closed as program error.
Error description
The customer attempted to create a cluster with two cluster members that have the same name (server_specific_name), but different short names in two different nodes, but the server failed on start with BBOM0057W message and DC3 abend. The server_specific_uuid in was.env of the cluster members has more than the 40-chars limit (the failed server_specific_uuid has 80 chars - to be exact). Here's the symptom: IEF403I DVSR99CS - STARTED - TIME=14.53.33 +BBOM0057W DEFAULT VALUE OF ENVIRONMENT VARIABLE server_specific_uuid USED. LENGTH MUST NOT EXCEED 40 CHARACTERS. . +CEE0374C CONDITION=CEE3250C TOKEN=00040CB2 61C3C5C5 00000000 WHILE RUNNING PROGRAM UNKNOWN AT THE TIME OF INTERRUPT ... BPXP018I THREAD 32B71A6000000000, IN PROCESS 51055530, ENDED WITHOUT BEING UNDUBBED WITH COMPLETION CODE 04DC3000, AND REASON CODE 04010001. IEF450I DVSR99CS DVSR99CS - ABEND=SDC3 U0000 REASON=04010001 TIME=14.53.34 IEF404I DVSR99CS - ENDED - TIME=14.53.34 $HASP395 DVSR99CS ENDED . and the server_specific_uuid in was.env of the cluster members had a value greater than 40-chars limit (80 chars - to be exact): server_specific_uuid=C3127481E00AC98B0000016C0000045A0AE8480DC31 274CA91AB45870000016C0000045A0AE8480D
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of WebSphere Application Server * * V7.0 * **************************************************************** * PROBLEM DESCRIPTION: Failure to start a cluster member * * when two cluster members have the * * same name but are in different nodes. * **************************************************************** * RECOMMENDATION: * **************************************************************** When two cluster members have the same name on different nodes, the cluster members cannot be started. During cluster creation, the configuration save operation generates the server_specific_uuid property incorrectly by concatenating the individual cluster member uuid's together since they have the same name. This causes the startup failure since the server_specific_uuid is limited to 40 characters. The following message is seen in the cluster member's log at startup: BBOM0057W DEFAULT VALUE OF ENVIRONMENT VARIABLE server_specific_uuid USED. LENGTH MUST NOT EXCEED 40 CHARACTERS.
Problem conclusion
The code has been fixed to properly generate the server_specific_uuid when more than one cluster member has the same name. This problem exists only on z/OS. APAR PK82690 is currently targeted for inclusion in Service Level (Fix Pack) 7.0.0.3 of WebSphere Application Server V7.0. Please refer to URL: //www.ibm.com/support/docview.wss?rs=404&uid=swg27006970 for Fix Pack availability.
Temporary fix
Comments
APAR Information
APAR number
PK82690
Reported component name
WEBSPHERE FOR Z
Reported component ID
5655I3500
Reported release
700
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-03-16
Closed date
2009-03-20
Last modified date
2009-05-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
BBGUBINF BBOUBINF
Fix information
Fixed component name
WEBSPHERE FOR Z
Fixed component ID
5655I3500
Applicable component levels
R700 PSY UK45160
UP09/04/06 P F904
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS7K4U","label":"WebSphere Application Server for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date: