Error description
Client using Rational Business Developer v7.1.0.2 VisalAge Generator compatibility issue: When an overlength character variable is assigned to a numeric variable, a numeric overflow exception is raised in EGL. This is different to the behavior in VAGen, which performs the MOVE, truncating leading digits, without raising a numeric overflow error.
Local fix
Problem summary
A move from character to zoned decimal was performing a numeric overflow check, whereas in VAG it was doing a truncated move.
Problem conclusion
Software updated. Fixtest EGLFixtest200812081453 is available for 7102 systems.
Temporary fix
Comments
APAR Information
APAR number
PK78536
Reported component name
RATL BUS DEV
Reported component ID
5724S5000
Reported release
710
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-01-13
Closed date
2009-03-20
Last modified date
2009-03-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL BUS DEV
Fixed component ID
5724S5000
Applicable component levels
R710 PSN
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]