A fix is available
APAR status
Closed as program error.
Error description
KO2O1365I NEAR-TERM HISTORY DATA COLLECTOR - SEQUENTIAL OUTPUT TO SYSP.OMEGAMON.xxxx.D2009005.T145933.RKD2S (ALLOCSEQ) CI0970: OMEGAMON SUBTASK ABEND CODE=04878000 PSW=070C100081567776 CI0971: PROGRAM NAME=KO2DMGRB IEA705I ERROR DURING GETMAIN SYS CODE = 878-10 CANSO2 CANSO2 IEA705I 00F4C000 00945088 00945088 00005200 0009FF68 KO2O1307I NEAR-TERM HISTORY DATA COLLECTOR IS TERMINATING KO2O1310I NEAR-TERM HISTORY DATA COLLECTOR SERVER KO2ISRVB HAS TERMINATED (SVESTAE ) When VSAMSEQ is specified, QSAM I/O is done using buffers below the 16M line. This can lead to excessive storage use when multiple DB2s are monitored. KEYWORDS: S878 SA78 SX78 ABENDS878 ABENDSA78 ABENDSX78
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - OMEGAMON collector * **************************************************************** * PROBLEM DESCRIPTION: BELOW 16-MEG LINE STORAGE CONSTRAINT * * USING VSAMSEQ * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: QSAM BUFFERS AND QSAM I/O ROUTINES ALLOCATED AND LOADED BELOW-THE-LINE. PROBLEM CONCLUSION: CHANGE CODE TO USE AVAILABLE 31-BIT QSAM METHODS. CHANGE MODULE AMODE(24) AND RMODE(24) WHENEVER POSSIBLE.
Problem conclusion
CHANGE CODE TO USE AVAILABLE 31-BIT QSAM METHODS. CHANGE MODULE AMODE(24) AND RMODE(24) WHENEVER POSSIBLE. KEYWORDS : BELOW 16-MEG STORAGE CONSTRAINT
Temporary fix
Comments
ž**** PE09/02/11 PTF IN ERROR. SEE APAR PK80459 FOR DESCRIPTION
APAR Information
APAR number
PK78458
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-01-12
Closed date
2009-02-04
Last modified date
2009-03-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
DUMM4KO2
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R410 PSN UK43757
UP09/02/06 P F902
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
10 March 2009