IBM Support

PK75846: DB2 ABEND REASON CODE 00C9021C WHEN A TABLE SPACE OR INDEX SPACEEXCEEDS 2GB

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The RBA is not incremented correctly in the target job when a
    space dataset exceeds 2GB. At that point, processing ends and no
    more pages are processed. This results in the DB2 abend. The
    code has been changed to increment the RBA correctly and
    continue processing past the 2GB boundary.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Cloning Tool.                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: The RBA is not incremented correctly    *
    *                      in the target job when a space dataset  *
    *                      exceeds 2GB. At that point, processing  *
    *                      ends and no more pages are processed.   *
    *                      This results in the DB2 abend. The      *
    *                      code has been changed to increment the  *
    *                      RBA correctly and continue processing   *
    *                      past the 2GB boundary.                  *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK75846

  • Reported component name

    DB2 CLONING TOO

  • Reported component ID

    5655N1000

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2008-11-18

  • Closed date

    2009-02-03

  • Last modified date

    2009-03-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK43743

Modules/Macros

  •    CKZ00530 CKZ00537 CKZ00545 CKZ00626 CKZ00629
    CKZ00632 CKZ00761 CKZ00762 CKZ00763
    

Fix information

  • Fixed component name

    DB2 CLONING TOO

  • Fixed component ID

    5655N1000

Applicable component levels

  • R210 PSY UK43743

       UP09/02/11 P F902

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0"}]

Document Information

Modified date: