A fix is available
APAR status
Closed as program error.
Error description
Dump Title: OMEGAMON II FOR DB2 DUMP: TASK=COMMCOLL,ID=V410 ,MOD=KO2CDB22,OFFSET=01905C,CODE=S0C4/00000004 ABEND0C4-4 KO2CTHS2+856 (PK70712) on a CLC instruction D5032004A2B6 with R2 bad. Also causes ABEND0C4-10 KO2XTHS2+1CC8 (level PK49696), R1 bad. Time of Error Information PSW: 07750000 80000000 00000000 179FD9EC ( KO2CTHSA + 85c ) Instruction length: 06 Interrupt code: 0004 Failing instruction text: D5032004 A2B64780 A24CD501 Breaking event address: 00000000_177E9DF0 GR 0-1 00000064_179FDB06 00000000_179FDB50 GR 2-3 00000000_00010000 00000000_7EFDA790 GR 4-5 00000000_17BADFD4 00000000_17BAEA88 GR 6-7 00000000_17BADFD8 00000000_17BB91B0 GR 8-9 00000000_00000000 00000000_00000010 GR 10-11 00000000_979FD8BA 00000000_17BAEE39 GR 12-13 00000000_17C9E128 00000000_17BAEA40 GR 14-15 00000000_979FD9E6 00000010_00000000 psw in KO2CTHSA at pk70712 level. Also: KO2I0170U S0C4 ABEND IN MODULE KO2XDB22 PERCOLATED TO D5API MODULE KO2ACONB Additional symptom: ABEND0C4-10 KO2XTHS2+1CC8 (PK49696) on a D5011000A2FC (CLC) instruction, R1 bad.
Local fix
Please apply PTF when available.
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - OMEGAMON Server * * - Common Collector * **************************************************************** * PROBLEM DESCRIPTION: ABEND0C4 O2CTHS+85C * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: Error recovery not set correctly. PROBLEM CONCLUSION: Set error recovery before checking storage area. KEYWORDS: ABENDS0C4 KO2CDB22 KO2CTHSA+85C
Problem conclusion
PROBLEM CONCLUSION: Set error recovery before checking storage area. KEYWORDS: ABENDS0C4 KO2CDB22 KO2CTHSA+85C
Temporary fix
Comments
APAR Information
APAR number
PK70953
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
410
Status
CLOSED PER
PE
YesPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2008-08-21
Closed date
2008-08-25
Last modified date
2017-02-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK39233
Modules/Macros
DGOVMDSP KD2PARSE KD2VRLS7 KO2CCISA KO2CCISS KO2CCIS2 KO2CCNSA KO2CCNSS KO2CCNS2 KO2CIFBB KO2CIFIA KO2CIFIS KO2CIFI2 KO2CTHMA KO2CTHMS KO2CTHM2 KO2CTH6A KO2CTH6S KO2CTH62 KO2CT2SA KO2CT2SS KO2CT2S2 KO2HMSGB KO2OCMAB KO2OCMCB KO2OCONB KO2OINTB KO2OMGCB KO2OMNUB KO2OTCIA KO2OTCIS KO2OTCI2 KO2OTHDB KO2OTHNB KO2OTH8B KO2OZPMB KO2RLOGH KO2XCISA KO2XCISS KO2XCIS2
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R410 PSY UK39233
UP08/08/27 P F808
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
04 February 2017