A fix is available
APAR status
Closed as program error.
Error description
Stopping the historical collector task does not free the dataset that was being used for sequential data collection. It is still allocated exclusive to the CANSO2 task. They are not freed. One user uses FLUSHJCL WRITEOPTION(VSAM,SEQ) in their coptxxxx For example: dataset name=SYSP.OMEGAMON.TS02.DMC1.D2008206.T155636 OWNERS= 1 ,WAIT EXCLUSIVE= ,WAIT SHARED= system=TS02 jobname=CANSO2 ,type=OWNER ,use=EXCLUSIVE . Additional Keywords: enqueue sequential vsam near term history
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - OMEGAMON collector * **************************************************************** * PROBLEM DESCRIPTION: SYSDSN ENQ for sequential dataset is * * not released when the historical * * collector is stopped. * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: The sequential dataset is not properly closed when the historical collector is stopped. PROBLEM CONCLUSION: Use the equivalent of FREE=CLOSE when dynamically allocating the sequential historical dataset. Drive the DCB CLOSE when the historical collector is stopped.
Problem conclusion
Use the equivalent of FREE=CLOSE when dynamically allocating the sequential historical dataset. Drive the DCB CLOSE when the historical collector is stopped. KEYWORDS : DCB CLOSE FREE=CLOSE SYSDSN ENQ HISTORICAL COLLECTOR
Temporary fix
Comments
APAR Information
APAR number
PK70079
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2008-08-04
Closed date
2008-10-16
Last modified date
2010-02-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK40772
Modules/Macros
KO2$QIOB KO2HDTIB
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R410 PSY UK40772
UP08/10/18 P F810
Fix is available