A fix is available
APAR status
Closed as program error.
Error description
SCA Component Reference intent list does not include transactedO neWay
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** SCA Policy Intents are in two categories: implementation intents which are added to components or component implementations, and interaction intents which are added to services and references. Due to some spec ambiguity, the transactedOneWay intent is in the category of implementation intents in RAD while it is in the category of interaction intents in WAS. This prevents the user from adding this intent onto services and references in RAD. The user can work around this by using XML editor to add the intent onto services or references.
Problem conclusion
The fix is to change the category of the intent from implementation to interaction in its extension definition in plugin.xml. Fixed in RAD v7.5.5.2
Temporary fix
Comments
APAR Information
APAR number
PM18616
Reported component name
RATL APP DEV LI
Reported component ID
5724J1902
Reported release
755
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-07-16
Closed date
2010-10-08
Last modified date
2010-10-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL APP DEV LI
Fixed component ID
5724J1902
Applicable component levels
R755 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSRTLW","label":"Rational Application Developer for WebSphere Software"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5.5","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date: