A fix is available
APAR status
Closed as new function.
Error description
Enhancements: - PROVIDE COMPATIBILITY WITH IMS TOOLS GENERIC EXITS. - PROVIDE SUPPORT FOR THE TRANSTAT= AND EXPRTIME= KEYWORD OF THE TRANSACT MACRO IN IMS V10. Corrections: - FAST PATH PSBS CAN SOMETIMES SHOW AS PGMTYPE=BATCH INSTEAD OF PGMTYPE=TP. - PROPERLY SET SYSGEN DEFINITION OF RESIDENT BITS IN PDIR AND DDIR (PDIRRESY and DDIRRESY) FOR IMS V10 AND V11. - USER SECURITY (HP SYSGEN OPTION 0.4) DOES NOT VALIDATE SECURITY VIA CLASS FACILITY PROFILE IOH.SETUP. - CSA MAP BY SUBPOOL AND KEY ABENDS WITH ABEND0C1 WHEN USER KEY CSA IS ALLOCATED. - PREVENT CREATION OF IMS GROUPS THAT START WITH IOH, AND PREVENT DISPLAY OF ANY GROUPS OR OTHER MEMBERS OF THE IOHOPT DATA SET THAT START WITH IOH. - HELP SCREEN IOHZ0040 CAN NOT BE DISPLAYED ON A 24 LINE TERMINAL. KEYWORDS: IMSV11TGT/K IMSV10TGT/K
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: IMS HIGH PERFORMANCE SYSGEN USERS. * **************************************************************** * PROBLEM DESCRIPTION: 1. Provide compatibility with IMS Tools * * Generic Exits. * * 2. Provide support for the TRANSTAT= * * and EXPRTIME= keywords of THE TRANSACT * * MACRO in IMS V10. * * 3. Correct several other items. * **************************************************************** * RECOMMENDATION: * **************************************************************** This APAR is making the following enhancements: 1. Provide compatibility with IMS Tools Generic Exits. 2. Provide support for the TRANSTAT= and EXPRTIME= keywords of the TRANSACT MACRO in IMS V10. This APAR is also making the following corrections: 1. Fast Path PSBS can sometimes show as PGMTYPE=BATCH instead of PGMTYPE=TP. 2. Properly set SYSGEN definition of resident bits in PDIR and DDIR (PDIRRESY/DDIRRESY) for IMS V10 and V11. 3. User security (HP SYSGEN OPTION 0.4) does not validate security via Class Facility Profile IOH.SETUP. 4. CSA Map by SUBPOOL and KEY abends with ABEND0C1 when user key CSA is allocated. 5. Prevent creation of IMS groups that start with IOH and prevent display of any groups or other members of the IOHOPT data set that start with IOH. 6. HELP screen IOHZ0040 can not be displayed on a 24 line terminal.
Problem conclusion
Temporary fix
Comments
The following changes have been made for the above enhancements: 1. Provide support for IMS Tools Generic Exits in IMS HP Sysgen Tools. 2. Add support for the TRANSTAT and EXPRTIME keywords of the TRANSACT MACRO in IMS V10. The following changes have been made for the above problems: 1. Properly set Fast Path PSB TYPE (BATCH or TP). 2. Update HP Sysgen to properly set PDIRRESY and DDIRESY in IMS V10/V11. 3. Add RACROUTE check for access to IOH.SETUP in Class Facility when accessing userid setup. 4. Fix error when processing user key CSA in CA MAP Utility. 5. Restrict IMS Group Names from starting with IOH. 6. Correct Panel IOHZ0040 to be 24 lines.
APAR Information
APAR number
PM16708
Reported component name
IMS HP SYSGEN T
Reported component ID
5655F4300
Reported release
220
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / Xsystem
Submitted date
2010-06-16
Closed date
2010-06-22
Last modified date
2010-08-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK58153
Modules/Macros
H24Q220J IOHA14 IOHCLST2 IOHCSA1 IOHDDIR0 IOHDDIR1 IOHDDIR7 IOHDDIR8 IOHDDIR9 IOHEDEX IOHEDEX0 IOHEDEX1 IOHFMAC IOHICL60 IOHICL61 IOHICL67 IOHICL68 IOHICL69 IOHJCLN0 IOHJCLN1 IOHJCLN7 IOHJCLN8 IOHJCLN9 IOHMBLK0 IOHMBLK1 IOHMBLK7 IOHMBLK8 IOHMBLK9 IOHMD071 IOHMD081 IOHMD091 IOHMD101 IOHMD111 IOHMWX IOHPDIR0 IOHPDIR1 IOHPDIR7 IOHPDIR8 IOHPDIR9 IOHPPUE0 IOHSDIR0 IOHSDIR1 IOHSDIR7 IOHSDIR8 IOHSDIR9 IOHTIME IOHXCSA IOHXGRP IOHXIMS IOHXINIT IOHXUSR IOHYT031 IOHYT032 IOHZCHK0 IOHZCHK1 IOHZCHK7 IOHZCHK8 IOHZCHK9 IOHZCTL0 IOHZCTL1 IOHZCTL7 IOHZCTL8 IOHZCTL9 IOHZCTU0 IOHZCTU1 IOHZCTU7 IOHZCTU8 IOHZCTU9 IOHZE010 IOHZGET0 IOHZGET1 IOHZGET7 IOHZGET8 IOHZGET9 IOHZINST IOHZMODA IOHZMODB IOHZRACF IOHZRCB0 IOHZRCB1 IOHZRCB7 IOHZRCB8 IOHZRCB9 IOHZUPD0 IOHZUPD1 IOHZUPD7 IOHZUPD8 IOHZUPD9 IOHZ0040
SC18947406 |
Fix information
Fixed component name
IMS HP SYSGEN T
Fixed component ID
5655F4300
Applicable component levels
R220 PSY UK58153
UP10/06/23 P F006
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89J","label":"IMS HP System Generation Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.2.0"}]
Document Information
Modified date:
22 October 2020