APAR status
Closed as program error.
Error description
User has a print form into which some blanks lines are printed. In the Rational Business Developer 7.5.1.4 generated cobol program, some blank lines are not printed. Instead a carriage control character appears where there should be a blank line. The problem did not occur in printforms created by VisualAge Generator.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** Users Affected: RBD 7.1.x and 7.5.x users printing an empty form (no variable or constant fields) to print a blank line(s) Problem Description: Blank lines were being suppressed since the + ASA character (no form feed) was getting printed on each blank line.
Problem conclusion
The empty print form was printed and a + ASA character was used, legitimately. On subsequent prints, the ASA character was not reset so a + was used from then on. The PSP generator was only generating the ASA reset for forms that contained a variable or constant for field. The reset should have been generated always.
Temporary fix
Comments
APAR Information
APAR number
PM13548
Reported component name
RBD EGL FOR COB
Reported component ID
5724S5001
Reported release
751
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-04-30
Closed date
2010-10-13
Last modified date
2010-10-13
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RBD EGL FOR COB
Fixed component ID
5724S5001
Applicable component levels
R751 PSN
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]