Error description
Dump Title: OMEGAMON II FOR DB2: COMPID=5655OPE00, JOB=OMXD23Y , LMOD=KOBAS510#L, CSECT=UNKNOWN , OFFSET=03C796 ABENDU0980 KOBSUB3M+5CC (at UA21255 level) issued following an ABEND0C4-4 KO2XTHSA+CE0 (at PK97646 level). The program check occurred on a D2FF22585100 (MVC) instruction because a pointer to the SPIB in R5 (DB2 control block) was bad. The same error occurs in KO2XTHS2+C90 (z/OS DB2 R810).
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - Classic Interface * **************************************************************** * PROBLEM DESCRIPTION: DUMP LMOD=KOBAS510#L, CSECT=UNKNOWN * * OFFSET=03C796, ABEND0C4 KO2XTHS OFFSET * * C94 * **************************************************************** * RECOMMENDATION: Apply this PTF * * * **************************************************************** PROBLEM SUMMARY: Incorrect length was used for the copying of stored procedure's data. PROBLEM CONCLUSION: Use the correct length for copying of stored procedure's data to prevent abend.
Problem conclusion
Use the correct length for copying of stored procedure's data to prevent abend. KEYWORDS : STORED PROCEDURE ABEND0C4 KO2XTHS C94
Temporary fix
Comments
APAR Information
APAR number
PM10623
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-03-23
Closed date
2010-05-19
Last modified date
2010-11-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
KO2CTHMA KO2CTHMS KO2CTHM2 KO2CT2SA KO2CT2SS KO2CT2S2 KO2OXSYB KO2XTHSA KO2XTHSS KO2XTHS2
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R410 PSY UK57070
UP10/05/21 P F005
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]