Troubleshooting
Problem
After Symantec Endpoint Protection updates, any report that executes results in an error message.
Cause
The BIBusTKServerMain will be prevented from being launched by the product.
Symantec identifies DLLs in the <cognos install>/bin directory as "WS.Reputation.1". Which does according to the description of this identification, is beyond the traditional signatures and behaviour-based detection, it uses a reputation-based system which polls individuals.
[code]https://www.symantec.com/security_response/writeup.jsp?docid=2010-051308-1854-99[/code]
Environment
Windows
Diagnosing The Problem
Symantec Endpoint Protection's risk logs will identify DLLs in the <cognos install>\bin as infected with "WS.Reputation.1".
Executing reports gives the error message gives the error message of:
DPR-ERR-2056 The Report Server is not responding.
The cogserver/cogaudit.log will contain the error:
CCL-PLG-0001 Failed to load the pluggable shared library
Resolving The Problem
Have your Security Administrator review the scan.
At which point, they will need to exclude the Cognos directory structure (and subfolders) from the scan.
Restore the quarantined files.
Restart the product.