Error description
When NTH collector cannot find the DB2 specified the message KO2O907W is issued and task is terminated with the user abend and dump produced : KO2O0907W OMEGAMON XE FOR DB2 PE TERMINATING BECAUSE DB2 NOT YET INITIALIZED IEA794I SVC DUMP HAS CAPTURED: DUMP TITLE=OMEGAMON II FOR DB2: COMPID=5655W3700, LMOD=KO2HWLMB#L, CSECT=O2HWLM, OFFSET=0021B4 The task should abnormally terminate without the dump. The KO2O907W message contains the appropriate information.
Local fix
Ignore the dump produced, the user abend is in accordance with product design and is not harmful.
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - Classic Interface * **************************************************************** * PROBLEM DESCRIPTION: DUMP IS PRODUCED WHEN DB2 IS * * TERMINATING. * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: A DUMP IS PRODUCED FOR MESSAGE KO2O0907W AND ABENDU1432. THIS DUMP IS NOT NEEDED. PROBLEM CONCLUSION: CODE IS CHANGED TO SKIP THIS DUMP. KEYWORDS: ABENDU1432 KO2O0907W NTH TERMINATION
Problem conclusion
CODE IS CHANGED TO SKIP THIS DUMP. KEYWORDS: ABENDU1432 KO2O0907W NTH TERMINATION
Temporary fix
Comments
APAR Information
APAR number
PM45695
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-08-15
Closed date
2011-10-04
Last modified date
2011-11-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK72595
Modules/Macros
KO2HWLMB KO2ORCVB
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R510 PSY UK72595
UP11/10/06 P F110
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]