A fix is available
APAR status
Closed as program error.
Error description
ABEND0C4 PIC04 or PIC11 occurred in csect DGOVHMM1 offset 01A4 after message FPEV3013E. General register 2 pointed to an address within a not accessible page of the storage. addtional keywords: LOAD MODULE DGOVHM00
Local fix
Reduce, if possible, the value set for HISTORYDATASETSIZE startup parameter since initializing of the history data set index has a high dispatching priority and therefore may cause the FPEV3013E "A TIMEOUT OCCURRED WHILE PROCESSING A REQUEST" message in response to requests coming to PE Server subtask from its clients. Do not connect to a corresponding instance neither from VTAM Classic Interface nor from Performance Expert client and do not perform shutdown of OMPE STC until the message FPEV0507I "... HISTORY MANAGER TASK STARTED" appears in the joblog.
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - PE Server subtask * * - Classic Interface * * - Performance Expert Client * **************************************************************** * PROBLEM DESCRIPTION: The ABEND S0C4 PIC04 or PIC11 * * occurs in CSECT DGOVHMM1 LMOD * * DGOVHM00. * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: ABEND S0C4 PIC04 or PIC11 occurred in LMOD DGOVHM00 CSECT DGOVHMM1 at offset 01A4 or 01A8 after appearance of one or several messages FPEV3013E. General register 2 pointed to an address within an inaccessible for the task page of the storage. PROBLEM CONCLUSION: The code of PE Server Subtask has been modified to solve this problem. KEYWORDS: S0C4 DGOVHMM1 FPEV3013E
Problem conclusion
PROBLEM CONCLUSION: The code of PE Server Subtask has been modified to solve this problem. KEYWORDS: S0C4 DGOVHMM1 FPEV3013E
Temporary fix
Comments
APAR Information
APAR number
PM43063
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
420
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-07-05
Closed date
2011-09-21
Last modified date
2017-06-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK72096 UK72097
Modules/Macros
DGOVDS DGOVHMM1 DGOVISI DGOVMSTR
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"420","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"420","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
16 June 2017