A fix is available
APAR status
Closed as program error.
Error description
Problem happened in ICBC production environment during a netbanking transaction. A TIMEOUT occurs (DB2 table resource not available) when Service Delivery CICS program calling Personal CICS program by DPL. Thus DB2 ROLLBACK happened which cause the "EXEC CICS SYNCPOINT" in Personal CICS transaction turned to "ROLLBACK NOHANLE". The RESPONSE is INVREQ as DPL not adding SYNCONRETURN parameter in Service Delivery CICS program, meanwhile EGL added RESPONSE parameter in the SYSCPONIT so the HANDLE was ineffective and turned to NOHANDLE, finally the program was not capture this exception.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: ALL USERS OF RATIONAL COBOL RUNTIME - RBD * **************************************************************** * PROBLEM DESCRIPTION: CORRECT ERROR HANDLING NEEDED * **************************************************************** * RECOMMENDATION: APPLY THIS MAINTENANCE * **************************************************************** CORRECT ERROR HANDLING NEEDED
Problem conclusion
CORRECT ERROR HANDLING NEEDED
Temporary fix
Comments
APAR Information
APAR number
PM42355
Reported component name
RATL COBOL RT Z
Reported component ID
5655R2900
Reported release
601
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-06-24
Closed date
2011-07-08
Last modified date
2011-08-01
APAR is sysrouted FROM one or more of the following:
PK95866
APAR is sysrouted TO one or more of the following:
Modules/Macros
ELASSCCM
Fix information
Fixed component name
RATL COBOL RT Z
Fixed component ID
5655R2900
Applicable component levels
R601 PSY UK69444
UP11/07/28 P F107
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSN27B","label":"Rational COBOL Runtime for zSeries"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0.1","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: