A fix is available
APAR status
Closed as program error.
Error description
When running AUDIT reports FPEUFUD2 may abend with an 0C4. The abend may be intermittent depending on what other IFCID are being processed through the reporter, FPECMAIN. The ABENDS0C4 is caused by incorrect processing of IFCID 145. When more data than IFCID145 is being processed the abend may not always happen. In the event this abend is encountered, please add a SYSMDUMP DD card to the batch reporting JCL per the following example //SYSMDUMP DD DSN=hilev.SYSMDUMP, // DISP=(NEW,CATLG,CATLG),UNIT=DASD, // SPACE=(CYL,(200,200),RLSE)
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - Batch Reporting * **************************************************************** * PROBLEM DESCRIPTION: Running AUDIT REPORTs in Omegamon DB2 * * Batch Reporter may result in an * * intermittent ABNDS0C4 in module * * FPEUFUD2. * * * **************************************************************** * RECOMMENDATION: Apply this PTF * * * **************************************************************** PROBLEM SUMMARY: QW0145 layout changed in V10. Long string copy performed using new V10 layout over V9 input data. That may cause ABEND0C4 in FPEUIFC2 to occur. PROBLEM CONCLUSION: Code changed to fix this problem.
Problem conclusion
Code changed to fix this problem. KEYWORDS : AUDIT BATCH REPORT RECORD TRACE ABEND0C4 FPEUFUD2
Temporary fix
Comments
APAR Information
APAR number
PM42205
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-06-22
Closed date
2011-07-14
Last modified date
2017-06-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK69750
Modules/Macros
FPEUFTDS FPEUFTS2 FPEUIFCI FPEUIFC2
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R510 PSY UK69750
UP11/07/15 P F107
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]