A fix is available
APAR status
Closed as program error.
Error description
The DB2 Administration Tool for z/OS batch WSL SYSPRINT DSN is not retrieved from the ADB2UCUS ISPF skeleton. . ISPF skeleton ADB2WL4 was not using the ADB2UCUS value due to missing customization. Customization step was overlooked due to missing sample job and ++HOLD DATA describing post-SMP/e customization step. . PRINTDSN variable is described in apar pm08490 for r720 ptf uk60356 : . Example ADB2UCUS setting for user to add : )CM USED IN SKEL ADB2WL4 WSL- WORK STATEMENT LIST )SET PRINTDSN = &ZUSER..&WORKLIST..SYSPRINT . In r720, once these statements are added to ADB2UCUS skeleton, and ptf uk60356 APPLY'd, the problem is resolved. . FFA10 In ra10, the example customization statements were not included in base level ADB2UCUS member of SADBSLIB. This apar will serve as a forward-fit of apar pm08490. . Reporting customer wanted to change HLQ for //SYSPRINT DD in the ADB2WL4 ISPF skeleton to use GOCPRE variable from DB2 Object Compare Tool for z/OS GOC5 panel. For the OC APPLY job in ra10, customer modified example customization statement in ADB2UCUS to use HLQ from &GOCPRE variable instead of &ZUSER variable shown above.
Local fix
Add the example customization statements to the ADB2UCUS ISPF skeleton member of SADBSLIB.
Problem summary
**************************************************************** * USERS AFFECTED: Users of the DB2 Administration Tool for * * z/OS Version 7.2 who use SAMP member * * member ADB2UCU6 to update skeleton * * ADB2UCUS. Users of the DB2 Administration * * Tool for z/OS Version 10.1 who will need to * * use ADB2UCU4, which is provided via this * * APAR. * **************************************************************** * PROBLEM DESCRIPTION: In the DB2 Administration Tool for * * z/OS, while running a Work Statement * * List (WSL) using batch job, the * * SYSPRINT DSN for the ADBTEP2 step * * is missing and fails with the following * * JCL error: * * * * IEF648I INVALID DISP FIELD- PASS * * SUBSTITUTED * * * * and the ADBWSPR DSN is also missing and * * fails with the following error: * * * * IEF212I ADBWSPR - DATA SET NOT FOUND * * STEP WAS NOT EXECUTED. * * * * As a result, the Load Summary Report * * step is not retrieved from the * * ADB2UCUS ISPF skeleton. The data sets * * are allocated using the TSO userid * * as the high level qualifier which * * might not be workable for the user. * * APAR PM08490 has already enabled * * retrieving customized SYSPRINT DSN * * from ADB2UCUS but missed the SAMPLE * * job and the ++HOLD DATA describing * * post-SMP/e customization steps. * * Also, the prefix of data sets from * * DB2 Object Compare/Change * * Management panel GOC5 ' Generate * * Compare Jobs' and panel ADB2CEX1 * * 'Run a Change' is not applied to * * WSL SYSPRINT DSN when the user * * choose to build the RUN WSL JCL * * during the COMPARE or ANALYZE * * change. * **************************************************************** * RECOMMENDATION: * **************************************************************** In the DB2 Administration Tool for z/OS, while running a Work Statement List (WSL) using batch job, the SYSPRINT DSN for the ADBTEP2 step is missing and fails with the following JCL error: IEF648I INVALID DISP FIELD- PASS SUBSTITUTED and the ADBWSPR DSN is also missing and fails with the following error: IEF212I ADBWSPR - DATA SET NOT FOUND STEP WAS NOT EXECUTED As a result, the Load Summary Report step is not retrieved from the ADB2UCUS ISPF skeleton. The data sets are allocated using the TSO userid as the high level qualifier which might not be workable for the user. APAR PM08490 has already enabled retrieving customized SYSPRINT DSN from ADB2UCUS but missed the SAMPLE retrieving customized SYSPRINT DSN from ADB2UCUS but missed the SAMPLE job and the ++HOLD DATA describing post-SMP/e customization steps. DB2 Object Compare/Change Management panel GOC5 ' Generate Compare Jobs' and panel ADB2CEX1 'Run a Change' is not applied to WSL SYSPRINT DSN when the user choose to build the RUN WSL JCL during the COMPARE or ANALYZE change.
Problem conclusion
Sample member ADB2UCU6 for DB2 Administration Tool for z/OS Version 7.2 and ADB2UCU4 for DB2 Administration Tool for z/OS Version 10.1 were added to provide the instructions on the post-SMP/e customization steps. Skeleton ADB2WL4 was modified by removing the building of the &PRINTDSN value let the value be retrieved from ADB2UCUS. This APAR also enables the prefix of data sets from DB2 Object Compare/Change Management panels GOC5 'Generate Compare Jobs' and panel ADB2CEX1 'Run a Change' to be applied to PRINTDSN when a user choose to be build the run WSL JCL during a COMPARE or ANALYZE change. After this APAR is applied, the user must perform the action described in the ++HOLD. If the instructions in ++HOLD is not followed, the &PRINTDSN will be blank, and running WSL in batch mode will fail with a JCL error due to a missing value for SYSPRINT DSN.
Temporary fix
Comments
APAR Information
APAR number
PM36340
Reported component name
DB2 ADMIN TOOL
Reported component ID
568851500
Reported release
A10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-04-05
Closed date
2011-06-27
Last modified date
2011-07-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK69177 UK69178
Modules/Macros
ADB2UCU4 ADB2UCU6 ADB2WL4 ADB2W1
Fix information
Fixed component name
DB2 ADMIN TOOL
Fixed component ID
568851500
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSCVQTD","label":"IBM Db2 Administration Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]