Error description
From the OMEGDB2 Collector job log: 2011/03/12 23:46:04 FPEV0224I MSTR INSTANCE FOR DB2 SUBSYSTEM DB5T STOPPED 2011/03/12 23:46:09 KO2O1324E NEAR-TERM HISTORY DATA COLLECTOR - DISCONNECT FROM DB2 FAILED. RETURN CODE 00000004 (CHECKRC 2011/03/12 23:46:09 KO2O1325E NEAR-TERM HISTORY DATA COLLECTOR - DISCONNECT FROM DB2 FAILED. REASON CODE 00C12824 (CHECKRC ) 2011/03/12 23:46:41 IEA794I SVC DUMP HAS CAPTURED: 009 009 DUMPID=001 REQUESTED BY JOB (OMEGDB2 ) 009 DUMP TITLE=OMEGAMON II FOR DB2: COMPID=5655OPE00, JOB=OMEGDB2 , 009 LMOD=KOBAS510#L, CSECT=UNKNOWN , OFFSET=05F976 2011/03/12 23:46:54 KO2S0500E OSNP SDUMPx Failure. RC: 00000B08 2011/03/12 23:46:54 KO2S0508E OSNP LMOD: KOBAS510, CSECT: UNKNOWN , OFFSET: 05F976 From the dump: a U980 abend was issued: PSW: 077D1000 920663EE Instruction length: 02 Interrupt code: 000D Failing instruction text: 00181610 0A0DD247 2000D000 Breaking event address: 00000000_00000000 AR/GR 0-1 00000000/00000000_80000000 00000000/00000000_800003D4 AR/GR 2-3 00000000/00000000_126A97C0 00000000/00000000_128720B0 AR/GR 4-5 00000000/00000000_126BC14C 00000000/00000000_126A9488 AR/GR 6-7 00000000/00000000_00000005 00000000/00000000_126BB968 AR/GR 8-9 00000000/00000000_126CE278 00000000/00000000_12872000 AR/GR 10-11 00000000/00000000_11E858FC 00000000/00000000_126BB968 AR/GR 12-13 00000000/00000000_126B37C0 00000000/00000000_0013AC00 AR/GR 14-15 00000000/126A0018_91E8590E 00000000/00000000_920663BA The U980 was issued at offset X'5EC' in OMSUB3 (V620COM 06/03/10 14:37 UA54637) From a VERBX LOGDATA: TCA: 120E5C30 RECDEBUG: 1266B6A8 Using the TCA, found 4 RECDEBUG entries the same as: *RECDEBUG entry 1 at Address 1266B4A8 +0000 PSW: PSW...... 077D0000 90469252 REGISTERS AT TIME OF ERROR: +0008 R0 - R4 : 104694D2 10469550 120E86F8 0DB33000 +0018 R4 - R7 : 00000000 E2C1E2E2 120E8F20 0DB33000 +0028 R8 - R11: 120E8750 120E8F20 90468FF8 0F434094 +0038 R12- R15: 126BD718 120E86F8 90469238 120E61D8 +0048 CR03..... 01400074 CR04..... 00010074 ABCC..... 000A0000 CMD...... EXSY ENT...... ........ ENTA..... 00000000 +0064 CALR..... ........ TYPE..... E2D7C9F1 ACT...... FF ALOW..... FF INTR..... FF SYS...... FF +0074 CRC...... 00000000 ATIM..... 00829DA3 0111071F RECDEBUG entry 5 is the U980. From a SYSTRACE: PGM 011 077D0000 90469252 00040011 00000000 00000000 00000000 0074 0074 23:46:40.360146 0DB33000 00000000 This S0C4 (from the SYSTRACE and RECDEBUG) happened in KO2CCNS at offset X'2B2' ( O2CCNS V420510 05/12/10 13:54.PM05666 DB2810 ) The instruction that fails is: 5830 3050 L @W3,SCOMASCE(,@W3) ASCE CHAIN ANCHOR ADDR R3 is 0DB33000, and from the dump: 0DB33000.:0DB3AFFF. LENGTH(X'8000')--Storage not available Looks like macro RECOVERY ON,LABEL=ALCNRECV started it all. Part of this macro does a lookup for TCA Entry SCOM - The entry in the $TCA is: 087 SCOM 0DB33000 00000000 0DB33000 is a bad address. Omegamon base Level 3 identified that the XODV code is in some sort of a loop. The $STACK area in the dump shows repetitive entries for XDRV and XDB1. That area is pointed to by W#STAKCP (x'314) in $OMWORK. In this case, $OMWORK is at x'13AC00'. . additional symptom: Dump Title: OMEGAMON II FOR DB2: COMPID=5655OPE00, JOB=OMXD2DX, LMOD=KOBAS510#L, CSECT=UNKNOWN, OFFSET=00162E RECDEBUG shows U980 abend is in OMSUB3. .
Local fix
no workaround
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - Classic Interface * **************************************************************** * PROBLEM DESCRIPTION: U980 ABEND AT OFFSET X'5EC' * * IN OMSUB3 AFTER LOOP IN OMEGAMON * * RECOVERY PROCESSING. * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: DB2 subsystem "not active" condition causes to abend during exception process. PROBLEM CONCLUSION: Change logic to properly handle exception process when DB2 subsystem is terminating.
Problem conclusion
Change logic to properly handle exception process when DB2 subsystem is terminating.
Temporary fix
Comments
APAR Information
APAR number
PM35517
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
420
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-03-24
Closed date
2011-06-20
Last modified date
2017-06-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK68923 UK68924 PM51940
Modules/Macros
HKDB510J KDB510J KO2CDFSA KO2CDFSK KO2CDFS2 KO2CDTMB KO2CSYSA KO2CSYSK KO2CSYS2 KO2OXCMB
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"420","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"420","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: