APAR status
Closed as program error.
Error description
The ELEMENTSECURITYPUT operation fails for WRITE, but works for READ settings in master element?
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * All Users * **************************************************************** * PROBLEM DESCRIPTION: * * See error description. * **************************************************************** * RECOMMENDATION: * * Upgrade to IBM Cognos TM1 9.5.2 FP1 or Upgrade to IBM Cognos * * TM1 10.1.0 * ****************************************************************
Problem conclusion
Code Fix
Temporary fix
Comments
APAR Information
APAR number
PM34660
Reported component name
TM1 TURBO INTEG
Reported component ID
5724W49TI
Reported release
951
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-03-11
Closed date
2012-02-15
Last modified date
2012-02-15
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TM1 TURBO INTEG
Fixed component ID
5724W49TI
Applicable component levels
R952 PSN
UP
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SS9RXT","label":"Cognos TM1"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.5.1","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
21 September 2021