Error description
The following egl code generates incorrect Cobol: Function AQA340P() MAFAMS.MKULTOP = 'AQA340P - UPDATE TA192'; try get TA1920R forUpdate AQA340P_RSI01 with #sql{ select NUMDNI, DNI, NIF, NOMBRE, FECALT, CODSIT, FECINC from sqlexp.ta192 T1 WHERE NUMDNI = :GNUMDNI for update of DNI, NIF, NOMBRE, FECALT, CODSIT, FECINC } into GNUMDNI, GDNI, GNIF, GNOMBRE1, GFECALT, GCODSIT, GFECINC ; onException AQA300G() ; end end // end AQA340P The Db2 bind step fails with sqlcode -503.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** The Select statement on the GET was modified to exclude some columns from the selection. The replace statement was using a default SET clause. Because of this, the SET clause contained columns that were not actually retrieved for update, causing a -503 during the bind step.
Problem conclusion
Because this is actually a problem that affects COBOL and Java/Debug, the fix was a change to the preprocessor. For replace satements that contain a default SET clause, and whose matching Get for Update contain a user modified SQL statement, the columns on the default SET clause are modified to only contain those (non-ReadOnly, non-Key) columns that were received into the INTO clause.
Temporary fix
Comments
APAR Information
APAR number
PM32785
Reported component name
RATL BUS DEV
Reported component ID
5724S5000
Reported release
751
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-02-15
Closed date
2011-05-06
Last modified date
2011-05-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL BUS DEV
Fixed component ID
5724S5000
Applicable component levels
R751 PSN
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
06 May 2011