A fix is available
APAR status
Closed as new function.
Error description
Allow IMS DL/I batch and BMP jobs to be restarted on a different version - maintenance level of IMS than the original job executed under. MSGIRT039E may be issued. Following is an example: IRT039E NO IMS1210 SUPPORT FOR IMS1110 EXTENDED RESTARTS
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IMS Program Restart Facility * **************************************************************** * PROBLEM DESCRIPTION: Provide support for restarting IMS * * jobs across different versions of IMS. * **************************************************************** * RECOMMENDATION: * **************************************************************** Provide support for restarting IMS jobs across different versions of IMS.
Problem conclusion
Temporary fix
Comments
Code has been added or modified that will allow IMS DL/I batch and BMP jobs to be restarted on a different version/ maintenance level of IMS than the original job executed under.
APAR Information
APAR number
PM32550
Reported component name
IMS PGM RESTART
Reported component ID
5655E1400
Reported release
210
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / Xsystem
Submitted date
2011-02-11
Closed date
2011-03-15
Last modified date
2013-01-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK65811
Modules/Macros
H23D210J IRTUM10B IRTUM11B IRTUM12B IRTUM51B IRTUM61B IRTUM71B IRTUM81B IRTUM91B IRT1011X IRT1012X IRT1110X IRT1112X IRT1210X IRT1211X
SC27091005 |
Fix information
Fixed component name
IMS PGM RESTART
Fixed component ID
5655E1400
Applicable component levels
R210 PSY UK65811
UP11/03/17 P F103
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSAVHR","label":"IMS Program Restart Facility for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]