A fix is available
APAR status
Closed as program error.
Error description
ZUTIA THREAD UTILITY Summary panel displays negative values in COUNT field for values more 2G when running utilities on very large tablespaces.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - Classic Interface * * - CUA Interface * **************************************************************** * PROBLEM DESCRIPTION: ZUTIA THREAD UTILITY SUMMARY PANEL * * DISPLAYS NEGATIVE VALUE IN COUNT FIELD * * FOR VALUES GREATER THAN 2GB. * * * **************************************************************** * RECOMMENDATION: Apply this PTF * * * **************************************************************** PROBLEM SUMMARY: FIELD COUNT IS DISPLAYED ON PANEL ZUTIA INCORRECTLY FOR VALUES EXCEEDING 2GB. PROBLEM CONCLUSION: FIELD COUNT IS INCREASED TO TEN DIGITS.
Problem conclusion
FIELD COUNT IS INCREASED TO TEN DIGITS. KEYWORDS: INCORROUT ZUTIA ZUTID ZUTIS PANEL COUNT 2GB
Temporary fix
Comments
APAR Information
APAR number
PM32383
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
420
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-02-10
Closed date
2011-05-02
Last modified date
2017-02-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK67303 UK67304
Modules/Macros
KD2OUDAD KD2OUDSD KD2OUSAD KD2OUSA2 KD29UDAD KD29USAD KD29USA2 KO2OTHCB KO2OUTLB
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"420","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"420","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
04 February 2017