Error description

  • Message IEF638I SPECIFIED NUMERIC EXCEEDS MAXIMUM ALLOWED IN THE
    UNIT FIELD may be issued due to an invalid unit count for the
    DISCARD DD.
    
    This can occur when the 'Max Tape Vols/DASD Units' utility
    option is set to greater than 59 and the 'Work File Unit Device'
    and / or 'Sort Work File Unit Device' job option is set to a
    tape device and templates are not used.
    

Local fix

  • Set the 'Generate Templates' job option to 'Y'
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Automation Tool.                *
    ****************************************************************
    * PROBLEM DESCRIPTION: Message IEF638I SPECIFIED NUMERIC       *
    *                      EXCEEDS MAXIMUM ALLOWED IN THE UNIT     *
    *                      FIELD may be issued due to an invalid   *
    *                      unit count for the DISCARD DD. This can *
    *                      occur when the 'Max Tape Vols/DASD      *
    *                      Units' utility option is set to greater *
    *                      than 59 and the 'Work File Unit Device' *
    *                      and / or 'Sort Work File Unit Device'   *
    *                      job option is set to a tape device and  *
    *                      templates are not used.                 *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM22543

  • Reported component name

    DB2 AUTOMATION

  • Reported component ID

    5697G6300

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2010-09-15

  • Closed date

    2011-01-17

  • Last modified date

    2011-02-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    HAA$BCPY
    

Fix information

  • Fixed component name

    DB2 AUTOMATION

  • Fixed component ID

    5697G6300

Applicable component levels

  • R310 PSY UK63995

       UP11/01/25 P F101

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310"}]

Document Information

Modified date:
30 March 2021