APAR status
Closed as program error.
Error description
Problem If you have a DXL attribute based on an enumerated type, you app ear to be able to edit its values using in-place editing. In fact no assigned values are retained, the DXL-assigned value is kept. Attempting to edit any other type of DXL attribute is not possib le, the in-place value fields are greyed out as per read-only at tributes. To Reproduce - create an enumeration type with e.g. 3 values: a, b and c - create a DXL attribute based on that type using code such as 'obj.attrDXLName = 'b' ' - add a column for the attribute to the view - double-click the column for an object, and drop the list of p otential values This list should not be shown, since the values in it can't be a ssigned manually. Possible Workarounds NA, cosmetic
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** A DXL attribute based on an enumerated type appear to be able to edit its values using in-place editing but the DXL generated values are retained once out of the in-place editing (or refresh).
Problem conclusion
While editing an enumerated attribute, the method that validates the read/write access of the user does not check for the DXL attribute type. This is corrected to check if theattribute is of DXL type. The user will not be able to see the drop down now.
Temporary fix
Comments
APAR Information
APAR number
PM19815
Reported component name
TLOGIC DOORS
Reported component ID
5724V61DR
Reported release
920
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-08-04
Closed date
2011-03-31
Last modified date
2011-03-31
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC DOORS
Fixed component ID
5724V61DR
Applicable component levels
R920 PSN
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSKR2T","label":"IBM Engineering Requirements Management DOORS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.2","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
01 May 2020