A fix is available
APAR status
Closed as program error.
Error description
Performance Warehouse abends S202 in module FPEZPMS then loops with repetitve S301 abends 04.03.40 STC17995 FPEV9999I **** DB2 PM/PE SYMPTOM RECORD **** 04.03.40 STC17995 FPEV9999I LVLS/OMEGAMON XE PE/PM 04.03.40 STC17995 FPEV9999I VALU/PCHK 04.03.40 STC17995 FPEV9999I AB/S/202 04.03.40 STC17995 FPEV9999I AB/U/000 04.03.40 STC17995 FPEV9999I RIDS/FPEZPMS#l 04.03.40 STC17995 FPEV9999I RIDS/ 04.03.40 STC17995 FPEV9999I PTFS/DA ? 04.03.40 STC17995 FPEV9999I ADRS/ 04.03.40 STC17995 FPEV9999I PSW /078C2000 814AF356 04.03.40 STC17995 FPEV9999I REGS 0-1/00000000 00000BD8 04.03.40 STC17995 FPEV9999I REGS 2-3/80010080 915766AA 04.03.40 STC17995 FPEV9999I REGS 4-5/00000000 0057666A 04.03.40 STC17995 FPEV9999I REGS 6-7/1076D4C8 00FC7880 04.03.40 STC17995 FPEV9999I REGS 8-9/014B0D48 00000000 04.03.40 STC17995 FPEV9999I REGS A-B/7F44BA18 7FFFBAF8 04.03.40 STC17995 FPEV9999I REGS C-D/00000BE0 00091330 04.03.40 STC17995 FPEV9999I REGS E-F/00FF1000 91491098 04.03.40 STC17995 IEA995I SYMPTOM DUMP OUTPUT 256 256 SYSTEM COMPLETION CODE=202 REASON CODE=00000000 256 TIME=04.03.40 SEQ=61906 CPU=0081 ASID=026D 256 PSW AT TIME OF ERROR 078C2000 814AF356 ILC 4 INTC 10 256 NO ACTIVE MODULE FOUND 256 NAME=UNKNOWN 256 DATA AT PSW 014AF350 - B20A2000 1F44BF43 503AB20A 256 GR 0: 00000000 1: 00000BD8 256 2: 80010080 3: 915766AA 256 4: 00000000 5: 0057666A 256 6: 1076D4C8 7: 00FC7880 256 8: 014B0D48 9: 00000000 256 A: 7F44BA18 B: 7FFFBAF8 256 C: 00000BE0 D: 00091330 256 E: 00FF1000 F: 91491098 256 END OF SYMPTOM DUMP 04.03.40 STC17995 FPEV9999I **** DB2 PM/PE SYMPTOM RECORD **** 04.03.40 STC17995 FPEV9999I LVLS/OMEGAMON XE PE/PM 04.03.40 STC17995 FPEV9999I VALU/SVCE 04.03.40 STC17995 FPEV9999I AB/S/301 04.03.40 STC17995 FPEV9999I AB/U/000 04.03.40 STC17995 FPEV9999I RIDS/FPEZPMS#l 04.03.40 STC17995 FPEV9999I RIDS/ 04.03.40 STC17995 FPEV9999I PTFS/DA ? 04.03.40 STC17995 FPEV9999I ADRS/ 04.03.40 STC17995 FPEV9999I PSW /070C1000 80FFAD84 04.03.40 STC17995 FPEV9999I REGS 0-1/80000000 80301000 04.03.40 STC17995 FPEV9999I REGS 2-3/00000B80 00000BD8 04.03.40 STC17995 FPEV9999I REGS 4-5/008C48C8 008C3B70 04.03.40 STC17995 FPEV9999I REGS 6-7/10F6B030 00FC7880 04.03.40 STC17995 FPEV9999I REGS 8-9/00000001 00FFB0F8 04.03.40 STC17995 FPEV9999I REGS A-B/00000BE0 008FEDB0 04.03.40 STC17995 FPEV9999I REGS C-D/00000080 00000001 04.03.40 STC17995 FPEV9999I REGS E-F/00FF1A62 00000000 04.03.40 STC17995 IEA995I SYMPTOM DUMP OUTPUT 275 275 SYSTEM COMPLETION CODE=301 275 TIME=04.03.40 SEQ=61907 CPU=0080 ASID=026D 275 PSW AT TIME OF ERROR 070C1000 80FFAD84 ILC 2 INTC 0D 275 NO ACTIVE MODULE FOUND 275 NAME=UNKNOWN 275 DATA AT PSW 00FFAD7E - 00181610 0A0DB219 00005820 275 AR/GR 0: 8F9CD47A/80000000 1: 00000000/80301000 275 2: 00000000/00000B80 3: 00000000/00000BD8 275 4: 00000000/008C48C8 5: 00000000/008C3B70 275 6: 00000000/10F6B030 7: 00000000/00FC7880 275 8: 00000000/00000001 9: 00000000/00FFB0F8 275 A: 00000000/00000BE0 B: 00000000/008FEDB0 275 C: 00000000/00000080 D: 00000000/00000001 275 E: 00000000/00FF1A62 F: 00000001/00000000 275 END OF SYMPTOM DUMP
Local fix
Turn off Performance Warehouse in RKD2PAR member(s)
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - Performance Warehouse users * **************************************************************** * PROBLEM DESCRIPTION: The Performance Warehouse (PWH) subtask * * load module FPEZPMS abends with code * * S202 followed by abends with code S301 * * in a loop. * * * **************************************************************** * RECOMMENDATION: Apply this PTF * * * **************************************************************** PROBLEM SUMMARY: The posting of an ECB in a list of ECBs fails. The consecutive call to the wait macro abends because the ECB had not been cleared. The abend handler returns control to the same code segment without clearing the ECB which results in a loop of abends S301. PROBLEM CONCLUSION: The code has been corrected to check the ECB before it gets posted. In case of abends Performance Warehouse will stop and issue the already existing message FPEV5002I.
Problem conclusion
The code has been corrected to check the ECB before it gets posted. In case of abends Performance Warehouse will stop and issue the already existing message FPEV5002I. KEYWORDS : ABEND S202 S301 FPEZPMS PWH
Temporary fix
Comments
APAR Information
APAR number
PM76269
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2012-11-01
Closed date
2012-12-05
Last modified date
2017-06-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK90058 UK90059
Modules/Macros
DGO@PC1 DGOVMSTR DGOZPC1 DGOZTEX
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: