Error description

  • v510 OMPE customer after logging onto Classic with the /C Candle
    default profile discovered a problem after adding a rule on the
    ZXTTCPU portion of the ZXTHD (P.B.B) panel:
    .
    ZXTHD (P.B.B) panel:
    : FUNCTION=ADD(01)  (DIS/ADD/DEL)
    +---------------------------------------------------------------
    + RULE=01 | Thread Exception Rule Parameters:
    :         |  PLAN=LINKAPP      AUTHID=________
    :         |  CICS Parameters:  CICSTRAN=____  CICSCONN=________
    :         |  IMS Parameters:   PSBNAME=_____  IMSID=________
    :         |  PACKDBRM=________
    :         |  PAKCOLID=__________________
    :         |  CORRID=____________
    :         |  REQLOC=________________
    :         |  THRDTYPE=__
    :         |  THRSHOLD=30       EXCLUDE=NO
    .
    Customer exited the ZXTTCPU panel, and re-entered it....Rule 01
    appeared as expected.
    .
    On the ZPROF panel, customer saved the Profile as "Installation"
    using (Option G)
    .
    Customer logged off of Classic and logged on again.as /C profile
    and chose CHANGE PROFILE (Option G) on ZPROF panel, changing the
    Profile to "Installation" (/I) on ZCHANGE panel and went back to
    the ZXTTCPU panel to examine the TCPU rules to see if RULE 01,
    which he had just added, was there
    .
    RULE 01  was not there .....the XTHD TCPU portion of the ZXTTCPU
    panel showed: FUNCTION=ADD(01) with blank fields.
    .
    When customer logs back into Classic as the /I profile, he can
    see the saved exception RULE 01 displayed on the ZXTTCPU panel.
    .
    Customer expected that by switching profiles from /C initially
    to the Installation profile (/I) that RULE 01 would have been
    displayed.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   Classic Interface                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: RULES OF CLASSIC EXCEPTIONS ARE NOT     *
    *                      RELOADED WHEN PROFILES ARE SWITCHED.    *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    *                                                              *
    ****************************************************************
    PROBLEM SUMMARY:
    1. Command CPRF and CPFI did not update the exception rules.
    2. Current thread exception rules and thread filters were
    deleted if an invalid profile was selected.
    3. Output of XMSG command was missed during profile switching
    in v510.
    4. ABEND0C4 happend in v510 when option TSF=ON had been set
    and then profile was switched.
    
    PROBLEM CONCLUSION:
    1. CPRF and CPFI will update the exception rules.
    2. Check has been added for valid selected profile before
    deleting previous exception rules and thread filters.
    3. Profile processing has been corrected in v510 to fix
    problem with missed output of XMSG command and option TSF=ON
    usage.
    4. V510 ABEND0C4 is corrected.
    

Problem conclusion

  • 1. CPRF and CPFI will update the exception rules.
    2. Check has been added for valid selected profile before
    deleting previous exception rules and thread filters.
    3. Profile processing has been corrected in v510 to fix
    problem with missed output of XMSG command and option TSF=ON
    usage.
    4. V510 ABEND0C4 is corrected.
    
    KEYWORDS : RULES CLASSIC EXCEPTIONS CPRF CPFI XMSG ABEND0C4
               TSF=ON
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM75806

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2012-10-24

  • Closed date

    2013-02-11

  • Last modified date

    2017-06-21

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK91551 UK91552

Modules/Macros

  •    KO2ODINB KO2OMGEB KO2OPRFB KO2OXTHB
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R510 PSY UK91551

       UP13/02/13 P F302

  • R511 PSY UK91552

       UP13/02/13 P F302

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
21 June 2017