A fix is available
APAR status
Closed as program error.
Error description
This APAR addresses the following problems: 1. Error message IOH4???E can be issued ( MSGIOH4???E ) 2. Attempting to reverse the history log can result in message IOHE031 (invalid field value(s) were encountered formatting the IOHLOG records - code D). MSGIOHE031 3. An incorrect transaction edit routine name can be shown in ISPF VIEW. 4. Changing the TRUNC option for a SPA from RTRUNC or STRUNC to "not specified" causes the old value to remain. 5. The ISPF VIEW option fails to show transaction Expry Time in a DRD environment. 6. Errors occur in a DRD environment when adding / updating a transaction - MODE=SNGL/MULT set incorrectly. - WFI=YES not being set. - FPATH= values not being interpreted correctly which can cause resource update list installation errors. - PROCLIM TIME value not being set to specified value.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: IMS High Performance Sysgen V2R2 users. * **************************************************************** * PROBLEM DESCRIPTION: Multiple issues with IMS HP Sysgen Tool * **************************************************************** * RECOMMENDATION: * **************************************************************** This APAR is addressing the following issues: 1.Error message IOH4???E can be issued. 2.Attempting to reverse the history log can result in an IOH031 message (invalid field value(s) were encountered formatting the IOHLOG records code D).This may occur using HP Sysgen option 8.2. 3.Incorrect transaction edit routine names can be shown in ISPF VIEW. 4.TRUNC processing is incorrect when applying a "not specified" value. 5.The ISPF VIEW option displays only the first 2 digits of transaction SYSIDs. 6.The VIEW options fails to load the proper IMS release dependent version of the RDDS read module. 7.Attempting to save a new IMSID options module before IMS environment information is obtained from the IMS control region results in ABEND0C4. 8.Several options may be set incorrectly when updating a transain a DRD environment.
Problem conclusion
The following changes have been made for the above issues: 1.Correct the invalid message number - to IOH2300E. 2.Correct an invalid length in an executed MVC instruction. 3.Change processing of transaction edit routine names to obtain them from DFSTRTnt instead of SMB resource extensions. 4.Update TRUNC processing to correct the value set for a "not specified" value. 5.Update the transaction VIEW display panel to allow 3 digit SYSIDs. 6.Correct the process of loading the release dependent module used to process an RDDS data set. 7.Prevent saving a new IMSID options module unless information has been obtained from the IMS control region. 8.Correct processing involved in setting options for transaction definition or update in a DRD environment.
Temporary fix
Comments
APAR Information
APAR number
PM75220
Reported component name
IMS HP SYSGEN T
Reported component ID
5655F4300
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2012-10-17
Closed date
2012-11-06
Last modified date
2012-12-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK83287
Modules/Macros
IOHA00 IOHEDEX IOHEDEX0 IOHEDEX1 IOHEDEX2 IOHRDDS IOHRDDS0 IOHRDDS1 IOHRDDS2 IOHTRNV1 IOHXIMS IOHXLOG2 IOHXSTOR IOHZCHK0 IOHZCHK1 IOHZCHK2 IOHZCHK7 IOHZCHK8 IOHZCHK9 IOHZCTL0 IOHZCTL1 IOHZCTL2 IOHZCTL7 IOHZCTL8 IOHZCTL9 IOHZCTU0 IOHZCTU1 IOHZCTU2 IOHZCTU7 IOHZCTU8 IOHZCTU9 IOHZDRD0 IOHZDRD1 IOHZDRD2 IOHZGET0 IOHZGET1 IOHZGET2 IOHZGET7 IOHZGET8 IOHZGET9 IOHZRCB0 IOHZRCB1 IOHZRCB2 IOHZRCB7 IOHZRCB8 IOHZRCB9 IOHZUPD0 IOHZUPD1 IOHZUPD2 IOHZUPD7 IOHZUPD8 IOHZUPD9
SC18947406 |
Fix information
Fixed component name
IMS HP SYSGEN T
Fixed component ID
5655F4300
Applicable component levels
R220 PSY UK83287
UP12/11/08 P F211
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89J","label":"IMS HP System Generation Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.2.0"}]
Document Information