Fixes are available
4.2.2 Interim Fix 2 (December 2012) for Tivoli Storage Productivity Center
Fix Pack 5.1.1.2 (September 2013) for Tivoli Storage Productivity Center
Fix Pack 5.1.1.5 (July 2014) for Tivoli Storage Productivity Center
4.2.2 Fix Pack 7 (July 2014) for Tivoli Storage Productivity Center
Fix Pack 5.1.1.6 (March 2015) for Tivoli Storage Productivity Center
4.2.2 Fix Pack 8 (March 2015) for Tivoli Storage Productivity Center
4.2.2 Fix Pack 9 (May 2015) for Tivoli Storage Productivity Center
4.2.2 Fix Pack 10 (August 2015) for Tivoli Storage Productivity Center
Fix Pack 5.1.1.9 (October 2015) for Tivoli Storage Productivity Center
Fix Pack 5.1.1.12 (October 2016) for Tivoli Storage Productivity Center
4.2.2 Fix Pack 3 (October 2012) for Tivoli Storage Productivity Center
Fix Pack 5.1.1.13 (February 2017) for Tivoli Storage Productivity Center
Fix Pack 5.1.1.14 (June 2017) for Tivoli Storage Productivity Center
Fix Pack 5.1.1.15 (Sept 2017) for Tivoli Storage Productivity Center
Fix Pack 5.1.1.0 (December 2012) for Tivoli Storage Productivity Center
Fix Pack 5.1.1.8 (July 2015) for Tivoli Storage Productivity Center
APAR status
Closed as program error.
Error description
A path error caused the affected LSS00 to LSS00 Metro Mirror ppr c pair got suspended. However, TPC-R did not suspend other pairs in the same MM session. The logs indicated there is an IndexOutOfBoundsException at that time which contributed to this not handling the suspension of other pairs correctly.
Local fix
Problem summary
A suspend event could be initially received on a "Defined" session that has copysets added. The suspend event from the LSS would be caught and set a flag on the suspend marker. Since the session is in a defined state it does not do anything with the event. However this will cause a mismatch with the suspend marker and the event listener. On subsequent events this mismatch will cause some of the LSS to LSS pairings to not receive the suspend event from the hardware.
Problem conclusion
Sessions in the defined state now have the marker initialized prior to the start command. This will ensure that the suspend marker and event listener are in synch.
Temporary fix
Comments
APAR Information
APAR number
PM71126
Reported component name
TPC FOR REPL Z/
Reported component ID
5608TRMZ0
Reported release
41B
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-08-17
Closed date
2012-08-22
Last modified date
2012-08-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TPC FOR REPL Z/
Fixed component ID
5608TRMZ0
Applicable component levels
R42B PSY
UP
R51B PSY
UP
Document Information
Modified date:
17 November 2021