A fix is available
APAR status
Closed as program error.
Error description
Switching Views in DOORS does not bring the focus back to the first column. Issue seen in 9.3.0.X, 9.4 and also in 8.2. Steps to reproduce: ============= A DOORS Client installed on English locale machine, with Left to Right orientation is being considered: 1. Open a module and add a few columns (more than 8-9) 2. Save this as a new view 3. Scroll to the extreme right so you can see the last column 4. Now switch to some other view which has 3-4 columns (say standard view) 5. You will see only a blank screen Impact: ---------- This can be confusing to the user and they would like all the views to be defaulted to the left hand side when selected so all data is displayed.
Local fix
Problem summary
User can be left with an empty view if there are less columns in a newly selected view.
Problem conclusion
Made the view reset to the left side whenever the view is changed,
Temporary fix
There is no workaround for this issue
Comments
This happens in versions of DOORS prior to DOORS 9.5.1.2. This i s a client side fix.
APAR Information
APAR number
PM71091
Reported component name
TLOGIC DOORS
Reported component ID
5724V61DR
Reported release
930
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-08-17
Closed date
2013-11-07
Last modified date
2013-11-07
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC DOORS
Fixed component ID
5724V61DR
Applicable component levels
R951 PSY
UP