A fix is available
APAR status
Closed as new function.
Error description
This APAR provides a small program enhancement (SPE). The BTS V4 SPE includes a support for IMS V13 and a fix for MQCONN/MQCONNX call. KEYWORDS: IMSV13TGT/K
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: BTS V4 USERS WITH IMS Version 13 or MQ * **************************************************************** * PROBLEM DESCRIPTION: This APAR enables BTS V4R1 to run on * * IMS Version 13 (5635-A04). * * It also includes MQCONNX call support * * for KW=DLI without changing it to * * MQCONN. * * It also includes a fix to put each * * MQCONN call output immediately on * * BTSOUT for KW=BMP. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** BTS is changed to support IMS Version 13 and MQCONNX call with KW=DLI. It is also changed to fix MQCONN outputs with KW=BMP.
Problem conclusion
Temporary fix
Comments
The IMS BTS User's Guide and Reference ( SC19-3230-01 ) will be updated with following changes: << Add on Chapter 2, IMS Batch Terminal Simulator terminology, Abbreviations>> . IMS Version 13 refers to IMS Version 13 Release 1. << Add on Chapter 13, Input for the playback utility, BTSALOG0 JCL requirements, CNTLCRDS control statement keywords>> IMSLEVEL= keyword 13 IMS Version 13
APAR Information
APAR number
PM70739
Reported component name
IMS BTS
Reported component ID
5655A1400
Reported release
410
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / Xsystem
Submitted date
2012-08-12
Closed date
2012-12-12
Last modified date
2013-10-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK90240
Modules/Macros
BTSALCP0 BTSCOFC0 BTSCOM00 BTSDBLEN BTSDVBI0 BTSMINT0 BTSMWRT0 BTSPC000 BTSRC000
SC19323001 |
Fix information
Fixed component name
IMS BTS
Fixed component ID
5655A1400
Applicable component levels
R410 PSY UK90240
UP12/12/15 P F212
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCBTY2","label":"IMS Batch Terminal Simulator"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.1.0"}]
Document Information
Modified date:
20 October 2020