A fix is available
APAR status
Closed as program error.
Error description
When running MFS Reversal, ABENDS0C4 can occur after reversing MFS source when one of the following conditions met: - When storage area for I/O buffer obtained by MFS Reversal is freed and other utility obtains the area immediately before MFS Reversal re-accesses. - When running on an environment freed storage area is not accessible. One of the environment is CLIST environment.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: IMS Library Integrity Utilities for z/OS, * * Version 2 Release 1 (FMID=H27P210) users who * * use the MFS Reversal utility or the MFS * * Compare utility. * **************************************************************** * PROBLEM DESCRIPTION: When MFS Reversal utility or MFS * * Compare utility runs, ABEND0C4 can * * occur after reversing MFS source files * * or comparing MFS control blocks. * * * * The ABEND0C4 is caused by accessing * * freed internal work area in the * * storage. It occurs when one of the * * following conditions met: * * * * - When the internal work area in the * * storage obtained by MFS Reversal * * utility or MFS Compare utility is * * freed and other utility obtains the * * area immediately before MFS Reversal * * utility or MFS Compare utility * * re-accesses. * * * * - When MFS Reversal utility or MFS * * Compare utility runs on an * * environment that freed area in the * * storage is not accessible. One of * * the environment is CLIST * * environment. * * * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** MFS Reversal utility and MFS Compare utility accesses freed internal work area in the storage when closing data sets after reversing MFS source files or comparing MFS control blocks. If one of the following conditions met, the internal work area is not accessible and ABEND0C4 occurs. - When the internal work area in the storage obtained by MFS Reversal utility or MFS Compare utility is freed and other utility obtains the area immediately before MFS Reversal utility or MFS Compare utility re-accesses. - When MFS Reversal utility or MFS Compare utility runs on an environment that freed area in the storage is not accessible. One of the environment is CLIST environment. This APAR fixes MFS Reversal utility and MFS Compare utility not to access the internal work area in the storage after the area is freed.
Problem conclusion
The following module has been modified to fix the problem. FABVCNTL
Temporary fix
Comments
APAR Information
APAR number
PM69050
Reported component name
IMS LIBR INTEG
Reported component ID
5655I4200
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2012-07-17
Closed date
2012-08-06
Last modified date
2012-09-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK80835
Modules/Macros
FABVCNTL
Fix information
Fixed component name
IMS LIBR INTEG
Fixed component ID
5655I4200
Applicable component levels
R210 PSY UK80835
UP12/08/07 P F208
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89N","label":"IMS Library Integrity Utilities"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: