A fix is available
APAR status
Closed as program error.
Error description
When generating printed reports using DOORS printing with a page setup where signatures are included, if the number of signatures (including the comments with those signatures) applied to the given baseline exceeds a single page, two issues are observed - both of which are unexpected- (1) the signatures at the bottom of page run past the bottom margin of the defined Page Setup (which can result in obscuring other footer information (2) the signatures that roll on to the top of the subsequent page (or pages) will overwrite and obscure the content of other signature information located at this same spot on the top of the page.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** When generating printed reports using DOORS printing with a page setup where signatures are included, if the number of signatures (including the comments with those signatures) applied to the given baseline exceeds a single page, two issues are observed - both of which are unexpected- (1) the signatures at the bottom of page run past the bottom margin of the defined Page Setup (which can result in obscuring other footer information (2) the signatures that roll on to the top of the subsequent page (or pages) will overwrite and obscure the content of other signature information located at this same spot on the top of the page.
Problem conclusion
The code has been changed so that the baseline signature information is now printed
Temporary fix
Comments
APAR Information
APAR number
PM68551
Reported component name
TLOGIC DOORS
Reported component ID
5724V61DR
Reported release
930
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-07-10
Closed date
2012-12-04
Last modified date
2012-12-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC DOORS
Fixed component ID
5724V61DR
Applicable component levels
R930 PSN