Error description
When using a FULL RTE, the started task contains a BASEHLEV variable that is not used and therefore results in a JCL error.
Local fix
Please try to remove or comment out the following line in your OMPE STC and restart it to see if the OMPE can be restarted // BASEHLEV=&RHILEV..&SYS..R,
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - ICAT * **************************************************************** * PROBLEM DESCRIPTION: For FULL RTE the BASEHLEV symbol is not * * set in some cases. This leads to a JCL * * error when starting up the OMPE * * collector. * * * **************************************************************** * RECOMMENDATION: Apply this PTF * * * **************************************************************** PROBLEM SUMMARY: The following JCL error occurs in case the JCL for a FULL RTE is wrong: 3 IEFC657I THE SYMBOL BASEHLEV WAS NOT USED The PTF changes the way how the symbol is set to make sure it always contains a valid value. PROBLEM CONCLUSION: The started task is now generated with a valid BASEHLEV symbol value for each use case.
Problem conclusion
The started task is now generated with a valid BASEHLEV symbol value for each use case. KEYWORDS : FULL RTE BASEHLEV
Temporary fix
Comments
APAR Information
APAR number
PM67779
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-06-27
Closed date
2012-07-20
Last modified date
2012-08-09
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK80423
Modules/Macros
KD2VERS KD261SB3
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R510 PSY UK80423
UP12/07/24 P F207
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]