IBM Support

PM66721: CKZ78203E SUBTASK 01, DATASET SNAP, RC=X'00000008, RS=X'00000004

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Error message "CKZ78203E Subtask 01,DATASET SNAP, RC=X'00000008,
    RS=X'00000004' may occur when using EMCAPI during the copy
    process.  The problem stems from the fact that the error is
    returned not just in a message but in the API call itself. Any
    API error (a 4 in this case) results in termination of the copy.
    The code will be changed to compare the API return with
    MAX-COPY-RC value and if not exceeded, copies will be allowed to
    continue. To allow copies to continue if this error is
    encountered, set MAX-COPY-RC=4 and MAX-RC=4.
    

Local fix

  • Correct the EMC copy environment to eliminate API return codes
    that exceed zero.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Cloning Tool.                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: Error message "CKZ78203E Subtask        *
    *                      01,DATASET SNAP, RC=X'00000008,         *
    *                      RS=X'00000004' may occur when using     *
    *                      EMCAPI during the copy process.  The    *
    *                      problem stems from the fact that the    *
    *                      error is returned not just in a         *
    *                      message but in the API call itself.     *
    *                      Any API error (a 4 in this case)        *
    *                      results in termination of the copy.     *
    *                      The code will be changed to compare     *
    *                      the API return with MAX-COPY-RC value   *
    *                      and if not exceeded, copies will be     *
    *                      allowed to continue. To allow copies    *
    *                      to continue if this error is            *
    *                      encountered, set MAX-COPY-RC=4 and      *
    *                      MAX-RC=4.                               *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM66721

  • Reported component name

    DB2 CLONING TOO

  • Reported component ID

    5655N1000

  • Reported release

    220

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-06-13

  • Closed date

    2012-07-23

  • Last modified date

    2012-08-08

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK80468

Modules/Macros

  •    CKZ00501 CKZ00782
    

Fix information

  • Fixed component name

    DB2 CLONING TOO

  • Fixed component ID

    5655N1000

Applicable component levels

  • R220 PSY UK80468

       UP12/07/26 P F207

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUUE","label":"IBM Db2 Cloning Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
12 February 2021