IBM Support

PM66299: SETTING DIAGNOSTICS PARAMETER EPTT RESULTS IN FALSE ALERT AND SDUMP

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Setting diagnostics parameter EPTT can result in a false alert
    SDUMP.
    For example, after this MODIFY command:
    F CANSO2,F PESERVER,F DB2A,EPTT=30
    .
    An SVC dump with this title was taken:
    Dump Title: FPEVDB2I - DB2 ADDRESS SPACES FOR DB2A
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   PE Server subtask                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1. When the Elapsed Processing Timeout  *
    *                      Threshold (EPTT) is set for the PE      *
    *                      Server subtask, message FPEV2103I is    *
    *                      issued followed by message FPEV2101I    *
    *                      and the corresponding dump although     *
    *                      the actual data retrieval requests      *
    *                      complete within the specified           *
    *                      threshold.                              *
    *                      2. When two OMEGAMON started tasks      *
    *                      are configured to monitor the same      *
    *                      DB2 subsystem on the same LPAR and      *
    *                      both are started, the monitoring PE     *
    *                      Server subtask which becomes attached   *
    *                      last abends with system completion      *
    *                      code 23E.                               *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    *                                                              *
    ****************************************************************
    PROBLEM SUMMARY:
    1. Depending on the MVS dispatching sequence of the PE Server
    subtasks, the subtask controlling the elapsed processing time
    for a data retrieval request might miss the completion of the
    request and thus falsly report a threshold violation.
    2. During termination the PE Server subtask tries to detach
    the DB2 interface subtask which was not attached before and
    is abended with S23E.
    
    PROBLEM CONCLUSION:
    1. The code has been modified to become independent of the MVS
    dispatching sequence of the PE Server subtasks.
    2. The code has been corrected. The already existing messages
    FPEV0164I, FPEV0015W and FPEV0224I are issued to report the
    situation.
    

Problem conclusion

  • 1. The code has been modified to become independent of the MVS
    dispatching sequence of the PE Server subtasks.
    2. The code has been corrected. The already existing messages
    FPEV0164I, FPEV0015W and FPEV0224I are issued to report the
    situation.
    
    KEYWORDS : FPEV2103I FPEV2101I EPTT FPEV0015W ABEND 23E
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM66299

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-06-06

  • Closed date

    2012-09-07

  • Last modified date

    2012-10-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK81596 UK81597

Modules/Macros

  • DGOVMSTR DGOVM002 FPEVDB2I FPEVM000
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R510 PSY UK81596

       UP12/09/11 P F209

  • R511 PSY UK81597

       UP12/09/11 P F209

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]