Error description

  • Provide a way to clone an IMS subsystem using dataset level
    copies to copy the source environment to the target.
    1. With RENAME these error/warning messages come out if target
    VVDS/VTOC does not match source.
    GCL11041E TARGET VOLUME IMS001 IS NOT IN A PROPER STATE FOR
    RENAME
    GCL11033W VOLUME CONVERSION BYPASSED FOR WAG049/IMS001 DUE TO
    PRIOR ERRORS
    2. IMSUPDATE needs to be able to execute if RENAME SIM is used.
    3. Provide option to list data sets that did not match a source
    in JCLPDS updating.
    4. Fix S0C4 when member in JCLPDS library is greater than 32K
    lines.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IMS Cloning Tool V1.1               *
    ****************************************************************
    * PROBLEM DESCRIPTION: Provide a way to clone an IMS subsystem *
    *                      using dataset level copies to copy the  *
    *                      source environment to the target.       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Provide a way to clone an IMS subsystem using dataset level
    copies to copy the source environment to the target.
    1. With RENAME these error/warning messages come out if target
    VVDS/VTOC does not match source.
    GCL11041E TARGET VOLUME IMS001 IS NOT IN A PROPER STATE FOR
    RENAME
    GCL11033W VOLUME CONVERSION BYPASSED FOR WAG049/IMS001 DUE TO
    PRIOR ERRORS
    2. IMSUPDATE needs to be able to execute if RENAME SIM is used.
    3. Provide option to list data sets that did not match a source
    in JCLPDS updating.
    4. Fix S0C4 when member in JCLPDS library is greater than 32K
    lines.
    

Problem conclusion

Temporary fix

Comments

  • 1.Add new IMS Subsystem Cloning keyword, ALLOW-RENAME-SIM, to
    IMSUPDATE command to indicate that the IMSUPDATE command can
    update IMS data sets even though the previous RENAME command
    was run with SIMULATE.
    2.Add new IMS Subsystem Cloning keyword, NOT-RENAMED-JCLPDS-
    LIST(N|Y), to IMSUPDATE command to specify whether a list of
    the data sets not renamed is to be produced by IMSUPDATE JCLPDS
    processing.
    3.Add new Database Cloning keyword, DBRC-ACTION(REDEFINE|
    REORG,ICOFF|NOICOFF), to IMSDBREFRESH command to indicate
    that DBRC action to perform for the target databases after
    refreshing them.
    4.Add new Database Cloning keyword, LOGICALLY-RELATED(Y|N),
    to IMSDBREFRESH command to indicate whether or not a database
    should be copied if not all logically related databases are
    copied in the same command.
    5.Add the following new parameters to the DB_COPY_OPTIONS
    section of GCLINI:
    DBRC_ACTION = REDEFINE|REORG
    SET_IC_NEEDED_OFF = Y/N
    6.  Add new message GCL32314I.
    

APAR Information

  • APAR number

    PM61866

  • Reported component name

    IMS CLONING TOO

  • Reported component ID

    5655U9100

  • Reported release

    110

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2012-04-04

  • Closed date

    2012-11-28

  • Last modified date

    2013-01-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK83839

Modules/Macros

  •    GCLEDIT  GCLINI#  GCL00310 GCL00320 GCL00323
    GCL00340 GCL00341 GCL00345
    

Fix information

  • Fixed component name

    IMS CLONING TOO

  • Fixed component ID

    5655U9100

Applicable component levels

  • R110 PSY UK83839

       UP12/12/05 P F212

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCBTY5","label":"IMS Cloning Tool"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.1.0"}]

Document Information

Modified date:
21 October 2020