A fix is available
APAR status
Closed as program error.
Error description
When a Char field with dateFormat=... is modified and left blank afterward the contents will be validated even properties Setting InputRequired is set to ' no' . An error will displayed : 'Input not valid for Defined date ......' Workaround : fill-in the date
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** When TextUIProgram converses a TextForm with a char field that has the dateFormat property, and the user types something in the field, then whatever the user typed must fit the specified date format. This is true even if the user typed into the field by mistake then erased their typing with Backspace, Delete, or by typing spaces. The EGL COBOL runtime can be configured to ignore the input in this case, and not give a validation error. But the EGL Java runtime does not have an equivalent setting.
Problem conclusion
A new Java runtime property has been added. Put vgj.datefield.valid.blanks=1 in the program's properties file to indicate that blanks in the field should not cause a validation error.
Temporary fix
Comments
APAR Information
APAR number
PM58353
Reported component name
RATL BUS DEV
Reported component ID
5724S5000
Reported release
750
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-02-16
Closed date
2012-03-15
Last modified date
2012-03-15
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL BUS DEV
Fixed component ID
5724S5000
Applicable component levels
R750 PSN
UP