Error description
Environment RFT 8.2.1.1 Windows XP SP3 AUT PowerBuilder 10.5 Problem description: First, selecting any datawindow in this map will show that what is used as a .name property is in fact the value of the Title given to the datawindow. This Title is also used as the value of the .text property. This therefore gives double the weight (150) to that title, while giving 0 weight to the real object name. The datawindow's name is indeed available to RFT, as it uses it as its Descriptive Name (#name) value. The PBWin32.DataWindowControlProxy should use THIS value for the .name recognition property, not the Title. Second, RFT places objects in the WRONG location in the map tree. This, because window recognition properties are not sufficiently unique. You will notice that there is a FNWND3105 window as a child of the MDI. This FNWND3105 window, in its turn, has ONE child FNWND3105 window, which contains all the objects seen on ALL tabs of the Test demo application. This is WRONG, as there should be one such child window for EACH tab in the application, and the controls within that tab should be appropriately located on the right child window.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** .name property is null for some windows in the application.
Problem conclusion
Fetching the .name property from the PB API.
Temporary fix
Comments
APAR Information
APAR number
PM58164
Reported component name
RAT FUNC TESTER
Reported component ID
5724G2503
Reported release
821
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-02-14
Closed date
2012-04-06
Last modified date
2012-04-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RAT FUNC TESTER
Fixed component ID
5724G2503
Applicable component levels
R821 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSJMXE","label":"IBM Rational Functional Tester"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"821","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
06 April 2012