A fix is available
APAR status
Closed as program error.
Error description
DOORS runs out of memory while exporting a module that is linked to a large number of modules (in this specific instance around 210 different modules).
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** Defect was occurring because when exported in table format many modules could be opened in background and also user might have selected export "all linked" modules and hence it opens many modules in GUI thus causing memory increase.
Problem conclusion
Fixed by applying memory management perms and also stopped opening linked modules in GUI.
Temporary fix
Comments
APAR Information
APAR number
PM56671
Reported component name
TLOGIC DOORS
Reported component ID
5724V61DR
Reported release
930
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-01-25
Closed date
2012-06-06
Last modified date
2012-06-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC DOORS
Fixed component ID
5724V61DR
Applicable component levels
R930 PSN
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSYQBZ","label":"Rational DOORS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.3","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]